Sharing Management Interfaces

Sharing Management Interfaces
POST http://<mgmt0_IP>/api/mo/sys/apphosting.json
{
    "apphostingAppHosting": {
        "attributes": {},
        "children" : [
            {
                "apphostingAppConf" : {
                    "attributes" : {
                        "adminSt": "enabled", 
                        "appId"  : "te_app"
 
                    },
                    "children" : [
                    {
                        "apphostingVnicEntry" : {
                            "attributes" : {
                                "adminSt": "enabled",
                                "hostIntf" : "management",
                                "guestIntfId" : "0"
                             }
                        }
                    },                  
]}}]}}


{
    "apphostingAppHosting": {
        "attributes": {},
        "children" : [
            {
                "apphostingAppConf" : {
                    "attributes" : {
                        "adminSt" : "disabled"                                                        
                        "appId"  : "te_app" 
                     }
                }
            }
        ]
    }
}
{
    imdata:[]
}


CLI Commands

The CLI commands are equivalent to the payload examples displayed in the pane on the right. Click the DME tab in the top-left corner of the right pane to view the JSON payload.

Configure an application

app-hosting appid te_app
 app-vnic management guest-interface 0
  exit

Unconfigure an application

no app-hosting appid te_app

Note: The property information for this example was added in release 10.3(1)F.


Verifying a DME Configuration
The following table contains the distinguished name (DN) for each managed object (MO) in the DME payload. Issue a GET request using the DN to verify the configuration was posted or to get information about the configured properties of a particular object.

MODN
apphostingAppHosting sys/apphosting
apphostingAppConf sys/apphosting/appconf-appid
apphostingVnicEntry sys/apphosting/appconf-appid/vnic-guestIntfId


appHostingVnicEntry Properties

The following table contains information about the appHostingVnicEntry properties in the DME payload. For more information about the properties and MOs, see the NX-API DME Model Reference linked in the Related Documentation section below.

Property NameData TypeValuesDescription
adminStscalar: Enum8Selection:
1: enabled
2: disabled
Default: disabled
Admin Status
hostIntfscalar: Enum8Selection:
0-management
1 to 8 - bridge 1-8
Default: management
Application host interface type
guestIntfIdscalar: Unit32Range: [1,3]
Default: 0
Guest interface identifier


Related Documentation

For other CLI options, see the Cisco Nexus 9000 Series NX-OS Command Reference:

http://www.cisco.com/c/en/us/support/switches/nexus-9000-series-switches/products-command-reference-list.html

See the NX-API DME Model Reference for detailed information about classes and attributes described in the payload:

https://developer.cisco.com/site/nx-os/docs/nexus-model-reference/

For information about using the payloads, see the Cisco Nexus 9000 Series NX-OS Programmability Guide:

https://www.cisco.com/c/en/us/support/switches/nexus-9000-series-switches/products-programming-reference-guides-list.html