Querying Inventory Information

Querying Inventory Information
GET http://<IP_Address>/api/mo/sys/ch.json
{
    "totalCount": "1",
    "imdata": [
        {
            "eqptCh": {
                "attributes": {
                    "childAction": "",
                    "descr": "Nexus9000 C9396PX Chassis",
                    "dn": "sys/ch",
                    "id": "1",
                    "mfgTm": "2014-03-17T00:00:00.000+00:00",
                    "modTs": "2018-06-06T15:07:25.086+00:00",
                    "model": "",
                    "operSt": "online",
                    "operStQual": "Chassis came online",
                    "persistentOnReload": "false",
                    "rev": "A0",
                    "role": "unsupported",
                    "ser": "SAL1812NT9M",
                    "status": "",
                    "vendor": "Cisco Systems, Inc."
                }
            }
        }
    ]
}
GET http://<IP_Address>/api/mo/sys/ch/spbp/spcmn.json
{
    "totalCount": "1",
    "imdata": [
        {
            "eqptSpCmnBlk": {
                "attributes": {
                    "cksum": "6342",
                    "clei": "CMMPE00DRB",
                    "count": "3",
                    "dn": "sys/ch/spbp/spcmn",
                    "engBits": "0",
                    "hwVer": "2.0",
                    "len": "160",
                    "major": "24578",
                    "mfgBits": "0",
                    "mfgDev": "00",
                    "minor": "0",
                    "oem": "Cisco Systems, Inc.",
                    "pRev": "A0",
                    "pdNum": "N9K-C9396PX",
                    "prtNum": "73-15605-04",
                    "pwrCon": "-3500",
                    "rmaFl": "0-0-0-0",
                    "serNum": "SAL1812NT9M",
                    "sig": "43947",
                    "size": "65535",
                    "vdrId": "V02",
                    "ver": "3"
                }
            }
        }
    ]
}
GET http://<IP_Address>/api/mo/sys/ch/ftslot-1/ft.json
{
    "totalCount": "1",
    "imdata": [
        {
            "eqptFt": {
                "attributes": {
                    "childAction": "",
                    "descr": "N9K-C9300-FAN2-1",
                    "dn": "sys/ch/ftslot-1/ft",
                    "fanName": "N9K-C9300-FAN2-1",
                    "hwVer": "1.0",
                    "id": "1",
                    "mfgTm": "not-applicable",
                    "modTs": "2018-06-06T14:16:20.128+00:00",
                    "model": "N9K-C9300-FAN2",
                    "operSt": "ok",
                    "persistentOnReload": "false",
                    "rev": "",
                    "ser": "",
                    "status": "",
                    "vdrId": "V01",
                    "vendor": ""
                }
            }
        }
    ]
}
GET http://<IP_Address>/api/mo/sys/ch/lcslot-1/lc.json
{
    "totalCount": "1",
    "imdata": [
        {
            "eqptLC": {
                "attributes": {
                    "breakoutFactor": "1",
                    "childAction": "",
                    "descr": "1/10G SFP+ Ethernet Module",
                    "dn": "sys/ch/lcslot-1/lc",
                    "hwVer": "2.0",
                    "id": "1",
                    "macB": "00-00-00-00-00-00",
                    "macE": "00-00-00-00-00-00",
                    "mfgTm": "2014-03-17T00:00:00.000+00:00",
                    "modTs": "2018-06-06T14:16:57.766+00:00",
                    "model": "N9K-C9396PX",
                    "numP": "48",
                    "operSt": "online",
                    "partNumber": "73-15605-04",
                    "persistentOnReload": "false",
                    "pwrSt": "on",
                    "rev": "A0",
                    "ser": "SAL1812NT9M",
                    "status": "",
                    "swCId": "298",
                    "swVer": "9.2(0.87)",
                    "type": "linecard",
                    "upTs": "2018-06-06T14:16:57.766+00:00",
                    "vdrId": "V02",
                    "vendor": "Cisco Systems, Inc."
                }
            }
        }
    ]
}
GET http://<IP_Address>/api/mo/sys/ch/psuslot-1/psu.json
{
    "totalCount": "1",
    "imdata": [
        {
            "eqptPsu": {
                "attributes": {
                    "cap": "54.160000",
                    "childAction": "",
                    "descr": "N9K-PAC-650W-1",
                    "dn": "sys/ch/psuslot-1/psu",
                    "drawnCurr": "6.177083",
                    "fanDirection": "front2back",
                    "fanOpSt": "ok",
                    "hwVer": "",
                    "id": "1",
                    "inputCurr": "0.364773",
                    "mfgTm": "not-applicable",
                    "modTs": "2018-06-11T16:21:40.496+00:00",
                    "model": "N9K-PAC-650W",
                    "operSt": "ok",
                    "persistentOnReload": "false",
                    "rev": "A0",
                    "ser": "DCB1749X0BB",
                    "status": "",
                    "vSrc": "220v",
                    "vdrId": "V01",
                    "vendor": "Cisco Systems Inc",
                    "volt": "12.000000"
                }
            }
        }
    ]
}
GET http://<IP_Address>/api/mo/sys/extch-150.json
{
    "totalCount": "1",
    "imdata": [
        {
            "eqptExtCh": {
                "attributes": {
                    "childAction": "",
                    "descr": "",
                    "dn": "sys/extch-150",
                    "extChSt": "ready",
                    "id": "150",
                    "macAddr": "7c:95:f3:4b:2c",
                    "mfgTm": "2013-08-12T01:00:00.000+00:00",
                    "modTs": "2018-06-06T14:19:05.000+00:00",
                    "model": "N2K-C2248TP-1GE",
                    "numMacs": "64",
                    "numUplinkP": "4",
                    "partNum": "68-3756-02",
                    "persistentOnReload": "false",
                    "rev": "",
                    "ser": "FOX1733G0TA",
                    "status": "",
                    "vendor": "Cisco Systems"
                }
            }
        }
    ]
}
GET http://<IP_Address>/api/mo/sys/extch-150/spbp/spcmn.json
{
    "totalCount": "1",
    "imdata": [
        {
            "eqptSpCmnBlk": {
                "attributes": {
                    "cksum": "1048",
                    "clei": "CMMBE00ARB",
                    "count": "1280",
                    "dn": "sys/extch-150/spbp/spcmn",
                    "engBits": "0",
                    "hwVer": "1280.0",
                    "len": "160",
                    "major": "352",
                    "mfgBits": "0",
                    "mfgDev": "0",
                    "minor": "0",
                    "oem": "Cisco Systems, Inc.",
                    "pRev": "A1",
                    "pdNum": "N2K-C2248TP-1GE",
                    "prtNum": "68-3756-02",
                    "pwrCon": "0",
                    "rmaFl": "0-0-0-0",
                    "serNum": "FOX1733G0TA",
                    "sig": "43947",
                    "size": "65535",
                    "vdrId": "V04",
                    "ver": "3"
                }
            }
        }
    ]
}
GET http://<IP_Address>/api/mo/sys/extch-150/extchslot-1/extchc.json
{
    "totalCount": "1",
    "imdata": [
        {
            "eqptExtChCard": {
                "attributes": {
                    "childAction": "",
                    "descr": "Fabric Extender 48x1GE + 4x10G Module",
                    "dn": "sys/extch-150/extchslot-1/extchc",
                    "fwVer": "",
                    "id": "99",
                    "macB": "7c-95-f3-4b-2c-c2",
                    "macE": "",
                    "mfgTm": "2013-07-29T01:00:00.000+00:00",
                    "modModel": "N2K-C2248TP-1GE",
                    "modSerial": "FOC17310ANA",
                    "modTs": "2018-06-06T14:19:05.065+00:00",
                    "modVendor": "Cisco Systems",
                    "model": "N2K-C2248TP-1GE",
                    "numP": "48",
                    "operSt": "inserted",
                    "partNum": "73-13232-02",
                    "partNumber": "",
                    "persistentOnReload": "false",
                    "pwrSt": "on",
                    "rdSt": "active",
                    "rev": "",
                    "ser": "FOC17310ANA",
                    "status": "",
                    "swCId": "99",
                    "swVer": "",
                    "type": "extchcard",
                    "upTs": "2018-06-06T14:19:05.065+00:00",
                    "vdrId": "",
                    "vendor": "Cisco Systems"
                }
            }
        }
    ]
}
GET http://<IP_Address>/api/mo/sys/extch-150/ftslot-1/ft.json
{
    "totalCount": "1",
    "imdata": [
        {
            "eqptFt": {
                "attributes": {
                    "childAction": "",
                    "descr": "Fan Module-1",
                    "dn": "sys/extch-150/ftslot-1/ft",
                    "fanName": "Fabric Extender Fan module",
                    "hwVer": "",
                    "id": "1",
                    "mfgTm": "not-applicable",
                    "modTs": "never",
                    "model": "N2K-C2248-FAN",
                    "operSt": "ok",
                    "persistentOnReload": "false",
                    "rev": "",
                    "ser": "N/A",
                    "status": "",
                    "vdrId": "",
                    "vendor": "N/A"
                }
            }
        }
    ]
}
GET http://<IP_Address>/api/mo/sys/extch-150/psuslot-1/psu.json
{
    "totalCount": "1",
    "imdata": [
        {
            "eqptPsu": {
                "attributes": {
                    "cap": "3300.000000",
                    "childAction": "",
                    "descr": "Power Supply 1",
                    "dn": "sys/extch-150/psuslot-1/psu",
                    "drawnCurr": "0.000000",
                    "fanDirection": "unknown",
                    "fanOpSt": "fail",
                    "hwVer": "",
                    "id": "1",
                    "inputCurr": "0.000000",
                    "mfgTm": "not-applicable",
                    "modTs": "never",
                    "model": "N2200-PAC-400W-B",
                    "operSt": "fail",
                    "persistentOnReload": "false",
                    "rev": "A0",
                    "ser": "LIT17341E0V",
                    "status": "",
                    "vSrc": "unknown",
                    "vdrId": "V02",
                    "vendor": "Cisco Systems, Inc.",
                    "volt": "12.000000"
                }
            }
        }
    ]
}
GET http://<IP_Address>/restconf/data/Cisco-NX-OS-device:System/stp-items
    
<ch-items>
    <descr>Nexus9000 C9396PX Chassis</descr>
    <ftslot-items>
        <FtSlot-list>
            <id>3</id>
            <descr>Fan Slot</descr>
            <ft-items>
                <descr>N9K-C9300-FAN2-3</descr>
                <fan-items>
                    <Fan-list>
                        <id>1</id>
                        <descr>fan</descr>
                        <dir>front2back</dir>
                        <mfgTm>not-applicable</mfgTm>
                        <model>N9K-C9300-FAN2</model>
                        <operSt>ok</operSt>
                        <rev/>
                        <ser/>
                        <speedInPercent>59</speedInPercent>
                        <speedInRpm>9872</speedInRpm>
                        <vendor>Cisco</vendor>
                    </Fan-list>
                </fan-items>
                <fanName>N9K-C9300-FAN2-3</fanName>
                <hwVer>1.0</hwVer>
                <id>3</id>
                <mfgTm>not-applicable</mfgTm>
                <model>N9K-C9300-FAN2</model>
                <operSt>ok</operSt>
                <rev/>
                <ser/>
                <vdrId>V01</vdrId>
                <vendor/>
            </ft-items>
            <loc>rear</loc>
            <operSt>empty</operSt>
            <physId>3</physId>
            <type>fantray</type>
        </FtSlot-list>
        <FtSlot-list>
            <id>2</id>
            <descr>Fan Slot</descr>
            <ft-items>
                <descr>N9K-C9300-FAN2-2</descr>
                <fan-items>
                    <Fan-list>
                        <id>1</id>
                        <descr>fan</descr>
                        <dir>front2back</dir>
                        <mfgTm>not-applicable</mfgTm>
                        <model>N9K-C9300-FAN2</model>
                        <operSt>ok</operSt>
                        <rev/>
                        <ser/>
                        <speedInPercent>59</speedInPercent>
                        <speedInRpm>9800</speedInRpm>
                        <vendor>Cisco</vendor>
                    </Fan-list>
                </fan-items>
                <fanName>N9K-C9300-FAN2-2</fanName>
                <hwVer>1.0</hwVer>
                <id>2</id>
                <mfgTm>not-applicable</mfgTm>
                <model>N9K-C9300-FAN2</model>
                <operSt>ok</operSt>
                <rev/>
                <ser/>
                <vdrId>V01</vdrId>
                <vendor/>
            </ft-items>
            <loc>rear</loc>
            <operSt>empty</operSt>
            <physId>2</physId>
            <type>fantray</type>
        </FtSlot-list>
        <FtSlot-list>
            <id>1</id>
            <descr>Fan Slot</descr>
            <ft-items>
                <descr>N9K-C9300-FAN2-1</descr>
                <fan-items>
                    <Fan-list>
                        <id>1</id>
                        <descr>fan</descr>
                        <dir>front2back</dir>
                        <mfgTm>not-applicable</mfgTm>
                        <model>N9K-C9300-FAN2</model>
                        <operSt>ok</operSt>
                        <rev/>
                        <ser/>
                        <speedInPercent>60</speedInPercent>
                        <speedInRpm>10055</speedInRpm>
                        <vendor>Cisco</vendor>
                    </Fan-list>
                </fan-items>
                <fanName>N9K-C9300-FAN2-1</fanName>
                <hwVer>1.0</hwVer>
                <id>1</id>
                <mfgTm>not-applicable</mfgTm>
                <model>N9K-C9300-FAN2</model>
                <operSt>ok</operSt>
                <rev/>
                <ser/>
                <vdrId>V01</vdrId>
                <vendor/>
            </ft-items>
            <loc>rear</loc>
            <operSt>empty</operSt>
            <physId>1</physId>
            <type>fantray</type>
        </FtSlot-list>
    </ftslot-items>
    <id>1</id>
    <lcslot-items>
        <LCSlot-list>
            <id>1</id>
            <descr>Linecard slot</descr>
            <lc-items>
                <breakoutFactor>1</breakoutFactor>
                <descr>1/10G SFP+ Ethernet Module</descr>
                <hwVer>2.0</hwVer>
                <id>1</id>
                <leafport-items>
                    <LeafP-list>
                        <id>5</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>41</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>52</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>53</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>26</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>9</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>24</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>40</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>25</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>27</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>14</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>6</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>1</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>36</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>46</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>21</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>7</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>37</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>44</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>50</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>47</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>38</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>54</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>45</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>31</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>8</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>15</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>23</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>3</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>17</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>30</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>16</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>18</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>49</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>33</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>12</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>43</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>51</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>13</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>39</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>29</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>2</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>19</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>4</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>35</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>10</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>34</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>20</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>11</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>32</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>28</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>22</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>42</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                    <LeafP-list>
                        <id>48</id>
                        <descr>Leaf Port</descr>
                        <speed>0</speed>
                        <type>leaf</type>
                    </LeafP-list>
                </leafport-items>
                <macB>00-00-00-00-00-00</macB>
                <macE>00-00-00-00-00-00</macE>
                <mfgTm>2014-03-17T00:00:00.000+00:00</mfgTm>
                <model>N9K-C9396PX</model>
                <numP>48</numP>
                <operSt>online</operSt>
                <partNumber>73-15605-04</partNumber>
                <pwrSt>on</pwrSt>
                <rev>A0</rev>
                <ser>SAL1812NT9M</ser>
                <splc-items>
                    <acc>read-only</acc>
                    <cap>512</cap>
                    <descr>Linecard Sprom</descr>
                    <id>1</id>
                    <numBlk>768</numBlk>
                    <operSt>ok</operSt>
                    <rev/>
                    <ser>SAL1812NT9M</ser>
                    <spcmn-items>
                        <cksum>6342</cksum>
                        <clei>CMMPE00DRB</clei>
                        <count>3</count>
                        <engBits>0</engBits>
                        <hwVer>2.0</hwVer>
                        <len>160</len>
                        <major>24578</major>
                        <mfgBits>0</mfgBits>
                        <mfgDev>00</mfgDev>
                        <minor>0</minor>
                        <oem>Cisco Systems, Inc.</oem>
                        <pRev>A0</pRev>
                        <pdNum>N9K-C9396PX</pdNum>
                        <prtNum>73-15605-04</prtNum>
                        <pwrCon>-3500</pwrCon>
                        <rmaFl>0-0-0-0</rmaFl>
                        <serNum>SAL1812NT9M</serNum>
                        <sig>43947</sig>
                        <size>65535</size>
                        <vdrId>V02</vdrId>
                        <ver>3</ver>
                    </spcmn-items>
                    <splcblk-items>
                        <ambT>55</ambT>
                        <cksum>2816</cksum>
                        <coolRq>100</coolRq>
                        <crdIdx>21022</crdIdx>
                        <eobcN>0</eobcN>
                        <epldN>0</epldN>
                        <fbits>0</fbits>
                        <hwCBits>64</hwCBits>
                        <len>103</len>
                        <macB>74-26-ac-76-64-00</macB>
                        <macL>56</macL>
                        <maxCPwr>8300</maxCPwr>
                        <sensor1>60,42</sensor1>
                        <sensor2>80,70</sensor2>
                        <sensor3>90,80</sensor3>
                        <sensor4>100,90</sensor4>
                        <sensor5>110,100</sensor5>
                        <sensor6>110,100</sensor6>
                        <sensor7>105,90</sensor7>
                        <sensor8>-128,-128</sensor8>
                        <sig>24579</sig>
                        <sppd-items>
                            <numPts>48</numPts>
                            <prtTy>2</prtTy>
                        </sppd-items>
                        <ver>2</ver>
                    </splcblk-items>
                    <spsensorblk-items>
                        <cksum>8368</cksum>
                        <len>71</len>
                        <sensor10>-128,-128</sensor10>
                        <sensor11>-128,-128</sensor11>
                        <sensor12>-128,-128</sensor12>
                        <sensor13>-128,-128</sensor13>
                        <sensor14>-128,-128</sensor14>
                        <sensor15>-128,-128</sensor15>
                        <sensor16>-128,-128</sensor16>
                        <sensor17>-128,-128</sensor17>
                        <sensor18>-128,-128</sensor18>
                        <sensor19>-128,-128</sensor19>
                        <sensor20>-128,-128</sensor20>
                        <sensor21>-128,-128</sensor21>
                        <sensor22>-128,-128</sensor22>
                        <sensor23>-128,-128</sensor23>
                        <sensor24>-128,-128</sensor24>
                        <sensor25>-128,-128</sensor25>
                        <sensor26>-128,-128</sensor26>
                        <sensor27>-128,-128</sensor27>
                        <sensor28>-128,-128</sensor28>
                        <sensor29>-128,-128</sensor29>
                        <sensor30>-128,-128</sensor30>
                        <sensor31>-128,-128</sensor31>
                        <sensor32>-128,-128</sensor32>
                        <sensor33>-128,-128</sensor33>
                        <sensor34>-128,-128</sensor34>
                        <sensor35>-128,-128</sensor35>
                        <sensor36>-128,-128</sensor36>
                        <sensor37>-128,-128</sensor37>
                        <sensor38>-128,-128</sensor38>
                        <sensor39>-128,-128</sensor39>
                        <sensor40>-128,-128</sensor40>
                        <sensor9>-128,-128</sensor9>
                        <sig>24584</sig>
                        <ver>1</ver>
                    </spsensorblk-items>
                    <type>unk</type>
                    <vendor/>
                </splc-items>
                <swCId>298</swCId>
                <swVer>9.2(0.87)</swVer>
                <type>linecard</type>
                <upTs>2018-06-06T14:16:57.766+00:00</upTs>
                <vdrId>V02</vdrId>
                <vendor>Cisco Systems, Inc.</vendor>
            </lc-items>
            <loc>front</loc>
            <operSt>empty</operSt>
            <physId>1</physId>
            <poweroff>no</poweroff>
            <purgeCfg>false</purgeCfg>
            <type>lcslot</type>
        </LCSlot-list>
        <LCSlot-list>
            <id>2</id>
            <descr>Linecard slot</descr>
            <lc-items>
                <breakoutFactor>1</breakoutFactor>
                <descr>40G Ethernet Expansion Module</descr>
                <hwVer>0.2080</hwVer>
                <id>2</id>
                <macB>00-00-00-00-00-00</macB>
                <macE>00-00-00-00-00-00</macE>
                <mfgTm>2014-06-30T01:00:00.000+00:00</mfgTm>
                <model>N9K-M6PQ</model>
                <numP>6</numP>
                <operSt>online</operSt>
                <partNumber>73-15578-02</partNumber>
                <pwrSt>on</pwrSt>
                <rev>08</rev>
                <ser>SAL1827W7TG</ser>
                <splc-items>
                    <acc>read-only</acc>
                    <cap>512</cap>
                    <descr>Linecard Sprom</descr>
                    <id>1</id>
                    <numBlk>768</numBlk>
                    <operSt>ok</operSt>
                    <rev/>
                    <ser>SAL1827W7TG</ser>
                    <spcmn-items>
                        <cksum>6806</cksum>
                        <clei>12345678</clei>
                        <count>3</count>
                        <engBits>0</engBits>
                        <hwVer>0.2080</hwVer>
                        <len>160</len>
                        <major>24578</major>
                        <mfgBits>0</mfgBits>
                        <mfgDev>00000000000000000000</mfgDev>
                        <minor>0</minor>
                        <oem>Cisco Systems, Inc.</oem>
                        <pRev>08</pRev>
                        <pdNum>N9K-M6PQ</pdNum>
                        <prtNum>73-15578-02</prtNum>
                        <pwrCon>-1333</pwrCon>
                        <rmaFl>0-0-0-0</rmaFl>
                        <serNum>SAL1827W7TG</serNum>
                        <sig>43947</sig>
                        <size>65535</size>
                        <vdrId>V00</vdrId>
                        <ver>3</ver>
                    </spcmn-items>
                    <splcblk-items>
                        <ambT>55</ambT>
                        <cksum>3216</cksum>
                        <coolRq>0</coolRq>
                        <crdIdx>21034</crdIdx>
                        <eobcN>0</eobcN>
                        <epldN>0</epldN>
                        <fbits>0</fbits>
                        <hwCBits>1</hwCBits>
                        <len>103</len>
                        <macB>88-f0-31-bd-34-9e</macB>
                        <macL>6</macL>
                        <maxCPwr>2400</maxCPwr>
                        <sensor1>105,95</sensor1>
                        <sensor2>105,95</sensor2>
                        <sensor3>110,100</sensor3>
                        <sensor4>-128,-128</sensor4>
                        <sensor5>-128,-128</sensor5>
                        <sensor6>-128,-128</sensor6>
                        <sensor7>-128,-128</sensor7>
                        <sensor8>-128,-128</sensor8>
                        <sig>24578</sig>
                        <sppd-items>
                            <numPts>6</numPts>
                            <prtTy>2</prtTy>
                        </sppd-items>
                        <ver>2</ver>
                    </splcblk-items>
                    <spsensorblk-items>
                        <cksum>8368</cksum>
                        <len>71</len>
                        <sensor10>-128,-128</sensor10>
                        <sensor11>-128,-128</sensor11>
                        <sensor12>-128,-128</sensor12>
                        <sensor13>-128,-128</sensor13>
                        <sensor14>-128,-128</sensor14>
                        <sensor15>-128,-128</sensor15>
                        <sensor16>-128,-128</sensor16>
                        <sensor17>-128,-128</sensor17>
                        <sensor18>-128,-128</sensor18>
                        <sensor19>-128,-128</sensor19>
                        <sensor20>-128,-128</sensor20>
                        <sensor21>-128,-128</sensor21>
                        <sensor22>-128,-128</sensor22>
                        <sensor23>-128,-128</sensor23>
                        <sensor24>-128,-128</sensor24>
                        <sensor25>-128,-128</sensor25>
                        <sensor26>-128,-128</sensor26>
                        <sensor27>-128,-128</sensor27>
                        <sensor28>-128,-128</sensor28>
                        <sensor29>-128,-128</sensor29>
                        <sensor30>-128,-128</sensor30>
                        <sensor31>-128,-128</sensor31>
                        <sensor32>-128,-128</sensor32>
                        <sensor33>-128,-128</sensor33>
                        <sensor34>-128,-128</sensor34>
                        <sensor35>-128,-128</sensor35>
                        <sensor36>-128,-128</sensor36>
                        <sensor37>-128,-128</sensor37>
                        <sensor38>-128,-128</sensor38>
                        <sensor39>-128,-128</sensor39>
                        <sensor40>-128,-128</sensor40>
                        <sensor9>-128,-128</sensor9>
                        <sig>24584</sig>
                        <ver>1</ver>
                    </spsensorblk-items>
                    <type>unk</type>
                    <vendor/>
                </splc-items>
                <swCId>329</swCId>
                <swVer>9.2(0.87)</swVer>
                <type>linecard</type>
                <upTs>2018-06-06T14:16:57.798+00:00</upTs>
                <vdrId>V00</vdrId>
                <vendor>Cisco Systems, Inc.</vendor>
            </lc-items>
            <loc>front</loc>
            <operSt>empty</operSt>
            <physId>2</physId>
            <poweroff>no</poweroff>
            <purgeCfg>false</purgeCfg>
            <type>lcslot</type>
        </LCSlot-list>
    </lcslot-items>
    <mfgTm>2014-03-17T00:00:00.000+00:00</mfgTm>
    <model/>
    <operSt>online</operSt>
    <operStQual>Chassis came online</operStQual>
    <psuslot-items>
        <PsuSlot-list>
            <id>2</id>
            <descr>PSU slot</descr>
            <loc>rear</loc>
            <operSt>empty</operSt>
            <physId>2</physId>
            <psu-items>
                <cap>54.16</cap>
                <descr>N9K-PAC-650W-2</descr>
                <drawnCurr>6.45</drawnCurr>
                <fanDirection>front2back</fanDirection>
                <fanOpSt>ok</fanOpSt>
                <hwVer/>
                <id>2</id>
                <inputCurr>0.36</inputCurr>
                <mfgTm>not-applicable</mfgTm>
                <model>N9K-PAC-650W</model>
                <operSt>ok</operSt>
                <rev>A0</rev>
                <ser>DCB1749X0C6</ser>
                <vSrc>220v</vSrc>
                <vdrId>V01</vdrId>
                <vendor>Cisco Systems Inc</vendor>
                <volt>12.0</volt>
            </psu-items>
            <type>psuslot</type>
        </PsuSlot-list>
        <PsuSlot-list>
            <id>1</id>
            <descr>PSU slot</descr>
            <loc>rear</loc>
            <operSt>empty</operSt>
            <physId>1</physId>
            <psu-items>
                <cap>54.16</cap>
                <descr>N9K-PAC-650W-1</descr>
                <drawnCurr>6.2</drawnCurr>
                <fanDirection>front2back</fanDirection>
                <fanOpSt>ok</fanOpSt>
                <hwVer/>
                <id>1</id>
                <inputCurr>0.36</inputCurr>
                <mfgTm>not-applicable</mfgTm>
                <model>N9K-PAC-650W</model>
                <operSt>ok</operSt>
                <rev>A0</rev>
                <ser>DCB1749X0BB</ser>
                <vSrc>220v</vSrc>
                <vdrId>V01</vdrId>
                <vendor>Cisco Systems Inc</vendor>
                <volt>12.0</volt>
            </psu-items>
            <type>psuslot</type>
        </PsuSlot-list>
    </psuslot-items>
    <rev>A0</rev>
    <role>unsupported</role>
    <ser>SAL1812NT9M</ser>
    <spbp-items>
        <acc>read-only</acc>
        <cap>0</cap>
        <descr>TOR</descr>
        <id>1</id>
        <model>TOR</model>
        <numBlk>3</numBlk>
        <operSt>ok</operSt>
        <rev>A0</rev>
        <ser>SAL1812NT9M</ser>
        <spbpblk-items>
            <cksum>1049</cksum>
            <fbits>0</fbits>
            <hwCBits>0</hwCBits>
            <len>39</len>
            <macB>00-00-ab-cd-dc-ba</macB>
            <macL>128</macL>
            <maxCPwr>0</maxCPwr>
            <oemEprise>0</oemEprise>
            <oemMIB>0</oemMIB>
            <sig>24577</sig>
            <stackMIB>0</stackMIB>
            <ver>3</ver>
        </spbpblk-items>
        <spcmn-items>
            <cksum>6342</cksum>
            <clei>CMMPE00DRB</clei>
            <count>3</count>
            <engBits>0</engBits>
            <hwVer>2.0</hwVer>
            <len>160</len>
            <major>24578</major>
            <mfgBits>0</mfgBits>
            <mfgDev>00</mfgDev>
            <minor>0</minor>
            <oem>Cisco Systems, Inc.</oem>
            <pRev>A0</pRev>
            <pdNum>N9K-C9396PX</pdNum>
            <prtNum>73-15605-04</prtNum>
            <pwrCon>-3500</pwrCon>
            <rmaFl>0-0-0-0</rmaFl>
            <serNum>SAL1812NT9M</serNum>
            <sig>43947</sig>
            <size>65535</size>
            <vdrId>V02</vdrId>
            <ver>3</ver>
        </spcmn-items>
        <type>7</type>
        <vendor>Cisco Systems, Inc.</vendor>
    </spbp-items>
    <supslot-items>
        <SupCSlot-list>
            <id>1</id>
            <descr>Sup slot</descr>
            <loc>front</loc>
            <operSt>empty</operSt>
            <physId>1</physId>
            <poweroff>no</poweroff>
            <sup-items>
                <cpu-items>
                    <CPU-list>
                        <id>1</id>
                        <arch>x86_64</arch>
                        <cores>4</cores>
                        <coresEn>4</coresEn>
                        <descr> Intel(R) Core(TM) i3- CPU # 2.50GHz</descr>
                        <mfgTm>not-applicable</mfgTm>
                        <model> Intel(R) Core(TM) i3- CPU # 2.50GHz</model>
                        <rev> 58</rev>
                        <ser>n/a</ser>
                        <sock>unspecified</sock>
                        <speed>2500.0</speed>
                        <thrds>4</thrds>
                        <vendor> GenuineIntel</vendor>
                    </CPU-list>
                </cpu-items>
                <descr>1/10G SFP+ Ethernet Module</descr>
                <dimm-items>
                    <Dimm-list>
                        <id>1</id>
                        <acc>read-write</acc>
                        <cap>16015</cap>
                        <descr>RAM</descr>
                        <mfgTm>2018-06-06T14:16:57.620+00:00</mfgTm>
                        <model>n/a</model>
                        <operSt>ok</operSt>
                        <rev>n/a</rev>
                        <ser>n/a</ser>
                        <type>dimm</type>
                        <vendor>n/a</vendor>
                    </Dimm-list>
                </dimm-items>
                <flash-items>
                    <acc>read-write</acc>
                    <cap>61057</cap>
                    <descr>flash</descr>
                    <id>1</id>
                    <mfgTm>2018-06-06T14:16:57.621+00:00</mfgTm>
                    <model>n/a</model>
                    <operSt>ok</operSt>
                    <rev>n/a</rev>
                    <ser>n/a</ser>
                    <type>flash</type>
                    <vendor>n/a</vendor>
                </flash-items>
                <hwVer>2.0</hwVer>
                <id>1</id>
                <macB>74-26-ac-76-64-00</macB>
                <macE>74-26-ac-76-64-37</macE>
                <mfgTm>2014-03-17T00:00:00.000+00:00</mfgTm>
                <mgmt-items>
                    <MgmtP-list>
                        <id>1</id>
                        <descr/>
                        <type>mgmt</type>
                    </MgmtP-list>
                </mgmt-items>
                <model>N9K-C9396PX</model>
                <numP>48</numP>
                <operSt>online</operSt>
                <partNumber>A0</partNumber>
                <pwrSt>on</pwrSt>
                <rdSt>active</rdSt>
                <rev>A0</rev>
                <sensor-items>
                    <Sensor-list>
                        <id>3</id>
                        <descr>CPU</descr>
                        <majorThresh>90</majorThresh>
                        <minorThresh>80</minorThresh>
                        <model>CPU</model>
                        <operSt>normal</operSt>
                        <tempValue>44</tempValue>
                        <type>cpu</type>
                        <unit>Celsius</unit>
                        <vendor>Cisco Systems</vendor>
                    </Sensor-list>
                    <Sensor-list>
                        <id>5</id>
                        <descr>NS-1</descr>
                        <majorThresh>105</majorThresh>
                        <minorThresh>90</minorThresh>
                        <model>NS-1</model>
                        <operSt>normal</operSt>
                        <tempValue>37</tempValue>
                        <type>asic</type>
                        <unit>Celsius</unit>
                        <vendor>Cisco Systems</vendor>
                    </Sensor-list>
                    <Sensor-list>
                        <id>1</id>
                        <descr>FRONT</descr>
                        <majorThresh>70</majorThresh>
                        <minorThresh>42</minorThresh>
                        <model>FRONT</model>
                        <operSt>normal</operSt>
                        <tempValue>28</tempValue>
                        <type>inlet</type>
                        <unit>Celsius</unit>
                        <vendor>Cisco Systems</vendor>
                    </Sensor-list>
                    <Sensor-list>
                        <id>4</id>
                        <descr>TD2-1</descr>
                        <majorThresh>105</majorThresh>
                        <minorThresh>90</minorThresh>
                        <model>TD2-1</model>
                        <operSt>normal</operSt>
                        <tempValue>43</tempValue>
                        <type>asic</type>
                        <unit>Celsius</unit>
                        <vendor>Cisco Systems</vendor>
                    </Sensor-list>
                    <Sensor-list>
                        <id>2</id>
                        <descr>BACK</descr>
                        <majorThresh>80</majorThresh>
                        <minorThresh>70</minorThresh>
                        <model>BACK</model>
                        <operSt>normal</operSt>
                        <tempValue>32</tempValue>
                        <type>outlet</type>
                        <unit>Celsius</unit>
                        <vendor>Cisco Systems</vendor>
                    </Sensor-list>
                </sensor-items>
                <ser>SAL1812NT9M</ser>
                <spsup-items>
                    <acc>read-only</acc>
                    <cap>512</cap>
                    <descr>Sup SPROM</descr>
                    <id>1</id>
                    <model>N9K-C9396PX</model>
                    <numBlk>768</numBlk>
                    <operSt>ok</operSt>
                    <rev>A0</rev>
                    <ser>SAL1812NT9M</ser>
                    <spcmn-items>
                        <cksum>6342</cksum>
                        <clei>CMMPE00DRB</clei>
                        <count>3</count>
                        <engBits>0</engBits>
                        <hwVer>2.0</hwVer>
                        <len>160</len>
                        <major>24578</major>
                        <mfgBits>0</mfgBits>
                        <mfgDev>00</mfgDev>
                        <minor>0</minor>
                        <oem>Cisco Systems, Inc.</oem>
                        <pRev>A0</pRev>
                        <pdNum>N9K-C9396PX</pdNum>
                        <prtNum>73-15605-04</prtNum>
                        <pwrCon>-3500</pwrCon>
                        <rmaFl>0-0-0-0</rmaFl>
                        <serNum>SAL1812NT9M</serNum>
                        <sig>43947</sig>
                        <size>65535</size>
                        <vdrId>V02</vdrId>
                        <ver>3</ver>
                    </spcmn-items>
                    <spsensorblk-items>
                        <cksum>8368</cksum>
                        <len>71</len>
                        <sensor10>-128,-128</sensor10>
                        <sensor11>-128,-128</sensor11>
                        <sensor12>-128,-128</sensor12>
                        <sensor13>-128,-128</sensor13>
                        <sensor14>-128,-128</sensor14>
                        <sensor15>-128,-128</sensor15>
                        <sensor16>-128,-128</sensor16>
                        <sensor17>-128,-128</sensor17>
                        <sensor18>-128,-128</sensor18>
                        <sensor19>-128,-128</sensor19>
                        <sensor20>-128,-128</sensor20>
                        <sensor21>-128,-128</sensor21>
                        <sensor22>-128,-128</sensor22>
                        <sensor23>-128,-128</sensor23>
                        <sensor24>-128,-128</sensor24>
                        <sensor25>-128,-128</sensor25>
                        <sensor26>-128,-128</sensor26>
                        <sensor27>-128,-128</sensor27>
                        <sensor28>-128,-128</sensor28>
                        <sensor29>-128,-128</sensor29>
                        <sensor30>-128,-128</sensor30>
                        <sensor31>-128,-128</sensor31>
                        <sensor32>-128,-128</sensor32>
                        <sensor33>-128,-128</sensor33>
                        <sensor34>-128,-128</sensor34>
                        <sensor35>-128,-128</sensor35>
                        <sensor36>-128,-128</sensor36>
                        <sensor37>-128,-128</sensor37>
                        <sensor38>-128,-128</sensor38>
                        <sensor39>-128,-128</sensor39>
                        <sensor40>-128,-128</sensor40>
                        <sensor9>-128,-128</sensor9>
                        <sig>24584</sig>
                        <ver>1</ver>
                    </spsensorblk-items>
                    <spsupblk-items>
                        <ambT>55</ambT>
                        <cksum>2807</cksum>
                        <coolRq>100</coolRq>
                        <crdIdx>21022</crdIdx>
                        <eobcN>0</eobcN>
                        <epldN>0</epldN>
                        <fbits>0</fbits>
                        <hwCBits>64</hwCBits>
                        <len>103</len>
                        <macB>74-26-ac-76-64-00</macB>
                        <macL>56</macL>
                        <maxCPwr>8300</maxCPwr>
                        <sensor1>60,42</sensor1>
                        <sensor2>80,70</sensor2>
                        <sensor3>90,80</sensor3>
                        <sensor4>100,90</sensor4>
                        <sensor5>110,100</sensor5>
                        <sensor6>110,100</sensor6>
                        <sensor7>105,90</sensor7>
                        <sensor8>-128,-128</sensor8>
                        <sig>24578</sig>
                        <sppd-items>
                            <numPts>48</numPts>
                            <prtTy>2</prtTy>
                        </sppd-items>
                        <ver>2</ver>
                    </spsupblk-items>
                    <type>flash</type>
                    <vendor>Cisco Systems, Inc.</vendor>
                </spsup-items>
                <swCId>298</swCId>
                <swVer>9.2(0.87)</swVer>
                <type>supervisor</type>
                <upTs>2018-06-06T14:16:57.616+00:00</upTs>
                <vdrId>V02</vdrId>
                <vendor>Cisco Systems, Inc.</vendor>
            </sup-items>
            <type>supslot</type>
        </SupCSlot-list>
    </supslot-items>
    <vendor>Cisco Systems, Inc.</vendor>
</ch-items>

The DME and YANG payloads correspond to the following show commands.

Note: This example was added in Cisco NX-OS Release 9.2(1).

CLI Output
Switch (config)# show inventory chassis
NAME: "Chassis",  DESCR: "Nexus9000 C9396PX Chassis"
PID: N9K-C9396PX         ,  VID: V02 ,  SN: SAL1812NT9M


Switch (config)# show inventory fans 
NAME: "Fan 1",  DESCR: "Nexus9000 C9396PX Chassis Fan Module"  
PID: N9K-C9300-FAN2      ,  VID: V01 ,  SN: N/A  
 


Switch (config)# show inventory module 1 
NAME: "Slot 1",  DESCR: "1/10G SFP+ Ethernet Module"            
PID: N9K-C9396PX         ,  VID: V02 ,  SN: SAL1812NT9M 


Switch (config)# show inventory power_supply 
NAME: "Power Supply 1",  DESCR: "Nexus9000 C9396PX Chassis Power Supply"
PID: N9K-PAC-650W        ,  VID: V01 ,  SN: DCB1749X0BB  



Switch (config)# show inventory fex 150 
NAME: "FEX 150 CHASSIS",  DESCR: "N2K-C2248TP-1GE  CHASSIS"              
PID: N2K-C2248TP-1GE     ,  VID: V04 ,  SN: FOX1733G0TA          



NAME: "FEX 150 Module 1",  DESCR: "Fabric Extender Module: 48x1GE, 4x10GE Supervisor"
PID: N2K-C2248TP-1GE     ,  VID: V04 ,  SN: FOC17310ANA          



NAME: "FEX 150 Fan 1",  DESCR: "Fabric Extender Fan module"            
PID: N2K-C2248-FAN       ,  VID: N/A ,  SN: N/A                  


NAME: "FEX 150 Power Supply 1",  DESCR: "Fabric Extender AC power supply"       
PID: N2200-PAC-400W-B    ,  VID: V02 ,  SN: LIT17341E0V

Note: The property information for this example was added in Release 9.3(3).


eqptCh Properties

The following table contains information about the eqptCh properties in the DME payload. For more information about the properties and MOs, see the NX-API DME Model Reference linked in the Related Documentation section below.

Property NameData TypeDescriptionValues
childAction
mo:ModificationChildAction
scalar:Bitmask32
Delete or ignore. For internal use only.SELECTION:
  • 16384u - deleteAll
  • 4096u - ignore
  • 8192u - deleteNonPresent
  • DEFAULT: 0
  • descreqpt:Descr
    Description of the specified attribute
    dn
    reference:BinRef
    A tag or metadata is a non-hierarchical keyword or term assigned to the fabric module.
    ideqpt:Id
    (scalar:Uint32)
    The item identifier.
    RANGE: [1 , 666]
    mfgTmscalar:Date
    Manufacturing TimeDATE FORMAT: %Y-%m-%dT%H:%M:%S.%f%z
    DEFAULT: not-applicable
    modTsmo:TStamp
    (scalar:Date)
    The time when this object was last modified.SELECTION:
    0 - never
    DEFAULT: never
    modeleqpt:Model
    (string:Basic)
    ModelA sequence of characters
    operSteqpt:ChOperSt
    (scalar:Enum8)
    online
    The operational status.
    SELECTION:
    0 - not-operational
    1 - failed
    2 - online
    DEFAULT: not-operational
    operStQualeqpt:OperStQual
    (string:Basic)
    Chassis came online
    The chassis operational status qualifier.
    A sequence of characters
    persistentOnReload
    mo:Persistent
    scalar:Enum8
    NO COMMENTSSELECTION:
  • 0 - false
  • 1 - true
  • DEFAULT: true(1)
  • reveqpt:Revision
    (string:Basic)
    RevisionA sequence of characters
    DEFAULT: 0
    roletop:NodeRole
    (scalar:Enum8)
    unsupported
    The role of this chassis
    SELECTION:
    0 - unsupported
    1 - controller
    2 - leaf
    3 - spine
    4 - vleaf
    5 - vip
    6 - protection-chain
    DEFAULT: unsupported
    sereqpt:Serial
    (naming:Name)
    Serial Number
    MAX SIZE: 16
    statusmo:ModificationStatus
    (scalar:Bitmask32)
    The upgrade status. This property is for internal use only.SELECTION:
    2 - created
    4 - modified
    8 - deleted
    16 - replaced
    vendoreqpt:Vendor
    (string:Basic)
    VendorA sequence of characters
    DEFAULT: Cisco Systems, Inc


    Related Documentation

    For other CLI options, see the Cisco Nexus 9000 Series NX-OS Command Reference:

    http://www.cisco.com/c/en/us/support/switches/nexus-9000-series-switches/products-command-reference-list.html

    See the NX-API DME Model Reference for detailed information about classes and attributes described in the payload:

    https://developer.cisco.com/site/nx-os/docs/nexus-model-reference/

    For information about using the payloads, see the Cisco Nexus 9000 Series NX-OS Programmability Guide:

    https://www.cisco.com/c/en/us/support/switches/nexus-9000-series-switches/products-programming-reference-guides-list.html