Configuring Hairpin Forwarding
Enabling Hairpin Forwarding on a Switchport
Enabling Hairpin Forwarding on a Switchport
POST http://<mgmt0_IP>/api/mo/sys/intf.json
{
"interfaceEntity": {
"children": [
{
"pcAggrIf": {
"attributes": {
"id": "po1234",
"layer": "Layer2",
"userCfgdFlags": "admin_layer"
},
"children": [
{
"pcAggrIfExtended": {
"attributes": {
"switchportVirtualEthernetBridge": "enable"
}}}]}}]}}
{
imdata:[]
}
<System>
<intf-items>
<aggr-items>
<AggrIf-list>
<id>po1234</id>
<layer>Layer2</layer>
<userCfgdFlags>admin_layer</userCfgdFlags>
<aggrExtd-items>
<switchportVirtualEthernetBridge>enable</switchportVirtualEthernetBridge>
</aggrExtd-items>
</AggrIf-list>
</aggr-items>
</intf-items>
</System>
Configures hairpin forwarding on a switchport. This is only compatible with the following switches:
- N9K-C9364C
- N9K-C92160YC-X
- N9K-C9348GC-FXP
- N9K-C93108TC-FX
- N9K-C93180YC-FX
- N9K-C92304QC
- N9K-C9272Q
- N9K-C9232C
- N9K-C9236C
- N9K-C92300YC
- N9K-C93108TC-EX
- N9K-C93180LC-EX
- N9K-C93180YC-EX
Note: This example was added in Release 7.0(3)I7(1).
CLI Commands
The CLI commands and options listed below are the equivalent to the payload examples displayed in the pane on the right. Click the DME tab in the top-left corner of the right pane to view the JSON payload or the YANG tab to view the XML payload.
interface port-channel 1234
switchport
switchport virtual-ethernet-bridge
For other CLI options, see the Cisco Nexus 9000 Series NX-OS Command Reference: http://www.cisco.com/c/en/us/support/switches/nexus-9000-series-switches/products-command-reference-list.html
See the NX-API DME Model Reference for detailed information about classes and attributes described in the payload: https://developer.cisco.com/site/nx-os/docs/nexus-model-reference/
For information about using the payloads, see the Cisco Nexus 9000 Series NX-OS Programmability Guide https://www.cisco.com/c/en/us/support/switches/nexus-9000-series-switches/products-programming-reference-guides-list.html
Enabling Hairpin Forwarding for an Ethernet Interface
Enabling Hairpin Forwarding for an Ethernet Interface
POST http://<mgmt0_IP>/api/mo/sys/intf.json
{
"interfaceEntity": {
"children": [
{
"l1PhysIf": {
"attributes": {
"id": "eth1/3"
},
"children": [
{
"l1PhysIfExtended": {
"attributes": {
"switchportVirtualEthernetBridge": "enable"
}}}]}}]}}
{
imdata:[]
}
<System>
<intf-items>
<phys-items>
<PhysIf-list>
<id>eth1/3</id>
<physExtd-items>
<switchportVirtualEthernetBridge>enable</switchportVirtualEthernetBridge>
</physExtd-items>
</PhysIf-list>
</phys-items>
</intf-items>
</System>
Note: This example was added in Release 7.0(3)I7(2).
CLI Commands
The CLI commands are equivalent to the payload examples displayed in the pane on the right. Click the DME tab in the top-left corner of the right pane to view the JSON payload. Click the YANG tab to view the XML payload.
interface ethernet 1/3
switchport virtual-ethernet-bridge
For other CLI options, see the Cisco Nexus 9000 Series NX-OS Command Reference: http://www.cisco.com/c/en/us/support/switches/nexus-9000-series-switches/products-command-reference-list.html
See the NX-API DME Model Reference for detailed information about classes and attributes described in the payload: https://developer.cisco.com/site/nx-os/docs/nexus-model-reference/
For information about using the payloads, see the Cisco Nexus 9000 Series NX-OS Programmability Guide https://www.cisco.com/c/en/us/support/switches/nexus-9000-series-switches/products-programming-reference-guides-list.html
Disabling Hairpin Forwarding for an Ethernet Interface
Disabling Hairpin Forwarding for an Ethernet Interface
POST http://<mgmt0_IP>/api/mo/sys/intf.json
{
"interfaceEntity": {
"children": [
{
"l1PhysIf": {
"attributes": {
"id": "eth1/3"
},
"children": [
{
"l1PhysIfExtended": {
"attributes": {
"switchportVirtualEthernetBridge": "disable"
}}}]}}]}}
{
imdata:[]
}
<System>
<intf-items>
<phys-items>
<PhysIf-list>
<id>eth1/3</id>
<physExtd-items>
<switchportVirtualEthernetBridge>disable</switchportVirtualEthernetBridge>
</physExtd-items>
</PhysIf-list>
</phys-items>
</intf-items>
</System>
Note: This example was added in Release 7.0(3)I7(2).
CLI Commands
The CLI commands are equivalent to the payload examples displayed in the pane on the right. Click the DME tab in the top-left corner of the right pane to view the JSON payload. Click the YANG tab to view the XML payload.
interface ethernet 1/3
no switchport virtual-ethernet-bridge
For other CLI options, see the Cisco Nexus 9000 Series NX-OS Command Reference: http://www.cisco.com/c/en/us/support/switches/nexus-9000-series-switches/products-command-reference-list.html
See the NX-API DME Model Reference for detailed information about classes and attributes described in the payload: https://developer.cisco.com/site/nx-os/docs/nexus-model-reference/
For information about using the payloads, see the Cisco Nexus 9000 Series NX-OS Programmability Guide https://www.cisco.com/c/en/us/support/switches/nexus-9000-series-switches/products-programming-reference-guides-list.html
Enabling Hairpin Forwarding on a Port Channel
Enabling Hairpin Forwarding on a Port Channel
POST http://<mgmt0_IP>/api/mo/sys/intf.json
{
"interfaceEntity": {
"children": [
{
"pcAggrIf": {
"attributes": {
"id": "po123"
},
"children": [
{
"pcAggrIfExtended": {
"attributes": {
"switchportVirtualEthernetBridge": "enable"
}}}]}}]}}
{
imdata:[]
}
<System>
<intf-items>
<aggr-items>
<AggrIf-list>
<id>po123</id>
<aggrExtd-items>
<switchportVirtualEthernetBridge>enable</switchportVirtualEthernetBridge>
</aggrExtd-items>
</AggrIf-list>
</aggr-items>
</intf-items>
</System>
Note: This example was added in Release 7.0(3)I7(2).
CLI Commands
The CLI commands are equivalent to the payload examples displayed in the pane on the right. Click the DME tab in the top-left corner of the right pane to view the JSON payload. Click the YANG tab to view the XML payload.
interface ethernet 1/2
interface port-channel 123
switchport virtual-ethernet-bridge
For other CLI options, see the Cisco Nexus 9000 Series NX-OS Command Reference: http://www.cisco.com/c/en/us/support/switches/nexus-9000-series-switches/products-command-reference-list.html
See the NX-API DME Model Reference for detailed information about classes and attributes described in the payload: https://developer.cisco.com/site/nx-os/docs/nexus-model-reference/
For information about using the payloads, see the Cisco Nexus 9000 Series NX-OS Programmability Guide https://www.cisco.com/c/en/us/support/switches/nexus-9000-series-switches/products-programming-reference-guides-list.html
Disabling Hair-Pin Forwarding on a Port Channel
Disabling Hairpin Forwarding on a Port Channel>
POST http://<mgmt0_IP>/api/mo/sys/intf.json
{
"interfaceEntity": {
"children": [
{
"pcAggrIf": {
"attributes": {
"id": "po123"
},
"children": [
{
"pcAggrIfExtended": {
"attributes": {
"switchportVirtualEthernetBridge": "disable"
}}}]}}]}}
{
imdata:[]
}
<System>
<intf-items>
<aggr-items>
<AggrIf-list>
<id>po123</id>
<aggrExtd-items>
<switchportVirtualEthernetBridge>disable</switchportVirtualEthernetBridge>
</aggrExtd-items>
</AggrIf-list>
</aggr-items>
</intf-items>
</System>
Note: This example was added in Release 7.0(3)I7(2).
CLI Commands
The CLI commands are equivalent to the payload examples displayed in the pane on the right. Click the DME tab in the top-left corner of the right pane to view the JSON payload. Click the YANG tab to view the XML payload.
interface ethernet 1/2
interface port-channel 123
no switchport virtual-ethernet-bridge
For other CLI options, see the Cisco Nexus 9000 Series NX-OS Command Reference: http://www.cisco.com/c/en/us/support/switches/nexus-9000-series-switches/products-command-reference-list.html
See the NX-API DME Model Reference for detailed information about classes and attributes described in the payload: https://developer.cisco.com/site/nx-os/docs/nexus-model-reference/
For information about using the payloads, see the Cisco Nexus 9000 Series NX-OS Programmability Guide https://www.cisco.com/c/en/us/support/switches/nexus-9000-series-switches/products-programming-reference-guides-list.html