Application Gateway Global Settings API
Use this API to retrieve global settings values for application gateway configurations. This is a read-only API.
URL
https://<server>/unifiedconfig/config/applicationgatewayglobalsettingOperations
-
list: Retrieves a list of values for the global configuration settings for each application gateway type. The only supported type is CUSTOM_GATEWAY.
Parameters
-
errorThreshold: Specifies the number of consecutive errors after which the router declares the Application Gateway host unavailable and tries to reconnect.
-
heartbeat: Information about the heartbeat, which includes the following parameters:
-
interval: The time in milliseconds the router waits between successful heartbeats.
-
limit: The number of consecutive missed heartbeats after which the router closes the connection and attempts to reconnect.
-
retry: How long in milliseconds the router waits before retrying a heartbeat after a heartbeat has failed.
-
timeout: How long in milliseconds the router waits for a response to a heartbeat before considering it a failure.
-
-
session: Information about the session, which includes the following parameters:
-
openTimeout: How long in milliseconds the router waits for a response to an open or close request. If it receives no response within this time, the router assumes the request failed.
-
retry: How long in milliseconds the router waits before trying to reconnect after a connection terminates or a connection attempts fails.
-
retryLimit: The number of times the router tries to establish the connection before it quits. If this limit is reached, you must restart the connection.
-
-
timeout: Information about the request, which includes the following parameters:
-
abandon: An internal timeout in milliseconds for communication between the router and the Application Gateway interface process. If a request exceeds this limit, the router assumes the Application Gateway interface process is off-line.
-
late: An internal timeout in milliseconds for communication between the router and the Application Gateway interface process. If a request exceeds this limit, the system software considers the request to be late.
-
request: How long in milliseconds the system software waits before timing out a request.
-
-
type: The type of application gateway. The only supported type is CUSTOM_GATEWAY.