Cisco Nexus 3000 and 9000 Series NX-API REST SDK User Guide and API Reference, Release 10.5(x)
Loading...
- Cisco Nexus 3000 and 9000 Series NX-API REST Documentation
- Cisco Nexus 3000 and 9000 Series NX-API REST SDK User Guide and API Reference, Release 10.5(x)
- Getting Started with the Cisco Nexus 3000 and 9000 Series NX-API REST SDK
- Related Documentation
- New and Changed Information
- Manageability
- ISSU Commands
- Installing Software Packages
- Configuring NX-API Management
- Managing Images
- Manageability Actions
- Configuring GRPC tunnel destination
- Manageability Using YANG (NETCONF)
- Configuring Fundamentals
- High Availability and Redundancy
- Configuring ITD
- Configuring Interfaces
- Configuring Ethernet Interfaces
- Configuring a MAC Address Limitation
- Configuring VLAN Interfaces
- Configuring Loopback Interfaces
- Configuring MGMT Interfaces
- Configuring Breakout Profiles
- Configuring System Default Switchport
- Configuring UDLD
- Configuring BFD
- Configuring LACP
- Configuring Hostname Loopback
- Configuring Breakout on High-Bandwidth Interfaces
- Configuring Port-Channel Interfaces
- Configuring Virtual Port Channels
- Configuring Tunnel Interfaces
- Configuring Layer 2 Protocol Tunneling
- Configuring Network Address Translation (NAT)
- Configuring IP TCP MSS
- Configuring Hardware Profile Settings
- Querying Interface Information
- Clearing Statistics
- Configuring IP SLAs
- Configuring Label Switching
- Configuring Segment Routing
- Configuring MPLS LDP
- Configuring Label Advertisement
- Configuring Label Allocation
- Configuring MPLS
- Disabling MPLS Forwarding for IP
- Configuring LDP Session Backoff
- Configuring LDP Discovery
- Configuring Explicit Null Label Advertisement
- Configuring LDP Graceful Restart
- Configuring LDP Holdtime
- Configuring a Neighbor
- Configuring an LDP Password
- Configuring LDP Logging
- Configuring LDP Labels
- Configuring an LDP Session
- Configuring MPLS LDP on an Interface
- Configuring Netstack
- Configuring Layer 2 Switching
- Configuring Flex Links
- Configuring Hairpin Forwarding
- Configuring Storm Control
- Configuring a Private VLAN (PVLAN)
- Configuring Multicast Routing
- Configuring PIM/PIM6
- Configuring MSDP
- Configuring IGMP
- Configuring MLD Snooping
- Configuring MRIB
- Configuring RPF Routes for Multicast
- Configuring Fabric Extender
- Configuring QoS
- Configuring Policing
- Configuring QoS Class Maps
- Configuring QoS Policy Maps
- Configuring a User-Defined Network QoS Policy
- Configuring the Hardware Buffer Utilization Thresholds
- Configuring Hardware QoS
- Configuring Hardware Profile Settings on the Cisco Nexus 3500 Platform
- Configuring Cisco Nexus 9000 (Cisco-ASIC based) Platform QoS
- Configuring Priority Flow Control
- Changing the Bandwidth Allocated to Unicast and Multicast Traffic
- Clearing Statistics
- Configuring TCAM
- Enabling Queue-Based ECN Marking
- Configuring Trust Boundaries
- Configuring Security
- Configuring FIPS Mode
- Configuring EAP Profile
- Configuring Keychain Management
- Configuring AAA
- Configuring RADIUS
- Configuring TACACS+
- Configuring LDAP
- Configuring SSH
- Configuring a Trustpool Policy
- Configuring a Trustpoint Certificate Authority
- Configuring a Trustpoint Certificate Authority
- Configuring Certificate Authority Related Information
- Crypto ca import for mytrustpoint pkcs12
- Configuring Telnet
- Configuring the Shell Type for Login
- Configuring User Accounts and RBAC
- Configuring the VSH Roles and Rules
- Configuring ACLs
- Configuring Port Security
- Configuring DHCP
- Configuring Password Encryption
- Configuring VPN Ids
- Configuring Unicast RPF (URPF)
- Configuring System Security Compliance
- Configuring Control Plane Policing
- Configuring Rate Limits
- Configuring MACsec
- Known Behaviour for Logging Level Configs
- Configuring System Management
- Configuring Sup Boot Variables
- Configuring System Cores
- Configuring System Trace Level
- Configuring the Fast Reload Network Stabilization Timer
- Configuring Frequency Synchronization
- Configuring NTP
- Configuring PTP
- Verifying PTP Counters
- Configuring Cisco Discovery Protocol
- Configuring Call Home
- Configuring Checkpoints and Rollback
- Configuring System Logging
- Configuring the Scheduler
- Configuring SNMP
- Configuring RMON
- Configuring Online Diagnostics
- Configuring EVMED
- Configuring Embedded Event Manager
- Configuring Memory Thresholds
- Configuring SPAN
- Configuring ERSPAN
- Configuring LLDP
- Enabling and Disabling LLDP
- Configuring LLDP in Global Mode
- Configuring LLDP on the if-eth-base/if-ethernet-all Command Mode
- Configuring LLDP on the if-gig-ether Command Mode
- Configuring LLDP on the if-gig-ether-all Command Mode
- Configuring LLDP on the if-mgmt-ether Command Mode
- Configuring the DCBXP Version
- Configuring System Interface Shutdown
- Configuring NetFlow
- Configuring Drop Report Tool
- Configuring sFlow
- Attaching a TAP Aggregation Policy to an Interface
- Configuring MPLS Stripping
- Configuring the Maintenance-Mode Profile
- Configuring Maintenance Mode
- Configuring CFS
- Configuring User-Defined Fields
- Configuring a Fan-Direction Mismatch
- System-Level High Availability
- Configuring NX-OS Container Tracker
- Configuring VXLAN
- VXLAN New and Changed
- Micro-segmentation for VXLAN Fabrics Using Group Policy Option (GPO)
- Configuring VXLAN BGP EVPN
- Configuring HMM
- Configure VXLAN FHS
- VXLAN Configuration Command Examples
- Configuring NVE Interfaces
- Configuring BGP EVPN Filtering
- Configuring VXLAN OAM (NGOAM)
- Executing Ping NVE, Traceroute NVE, and Path Trace NVE
- Configuring System NVE
- Associating NVE Interfaces with VNIs
- Configuring ngMVPN
- Configuring Selective Q-in-VNI
- Ephemeral (MOTL) MOs for NVE
- Configuring Unicast Routing
- Configuring the System Routing Mode
- Configuring ARP
- Configuring ALPM
- Configuring Logging for Software Forwarding of IP Packets
- Configuring DNS
- Configuring OSPF, OSPFv2, and OSPFv3
- Configuring OSPF
- Configuring OSPFv2
- Configuring OSPFv3
- Configuring an IPv6 Unicast Address Family Under an OSPFv3 Instance
- Configuring OSPFv3 Broadcast Network Type
- Configuring OSPFv3 on an Ethernet Interface
- Configuring OSPFv3 on a Loopback Interface
- Configuring OSPFv3 on a MGMT Interface
- Configuring OSPFv3 on a P2P Ethernet Interface
- Configuring OSPFv3 on a Tunnel Interface
- Configuring a Virtual Link Under an OSPFv3 Instance
- Configuring a VRF Under an OSPFv3 Instance
- Querying OSPFv3
- Configuring IS-IS
- Configuring IS-IS in Global Configuration Command Mode
- Configuring IS-IS in Interface Configuration Mode
- Configuring IS-IS in Router Configuration Mode
- Configuring IS-IS in Router VRF Configuration Mode
- Configuring IS-IS in Router IPv4 Address Family Configuration Mode
- Configuring IS-IS in Router IPv6 Address Family Configuration Mode
- IS-IS Operational Commands
- Configuring EIGRP
- Enabling EIGRP
- Disabling EIGRP
- Configuring isolate Under EIGRP
- Configuring flush-routes under EIGRP
- Configuring vrf
- Configuring EIGRP address-family
- Configuring EIGRP router-id
- Configuring EIGRP distance
- Configuring EIGRP maximum paths
- Configuring EIGRP default information originate
- Configuring EIGRP administrative state
- Configuring IPV4 EIGRP route redistribution
- Configuring IPv6 EIGRP route redistribution
- Configuring EIGRP table map filter
- Configuring EIGRP redistribute maximum prefix
- Configuring EIGRP graceful restart
- Configuring EIGRP log adjacency changes
- Configuring EIGRP log adjacency warnings
- Configuring EIGRP metric version
- Configuring EIGRP metric maximum hops
- Configuring EIGRP nsf await redistribute proto convergence
- Configuring EIGRP autonomous system number
- Configuring EIGRP nsf route-hold timer
- Configuring EIGRP nsf converge timer
- Configuring EIGRP nsf signal timer
- Configuring EIGRP timers active-time
- Configuring EIGRP supress fib pending
- Configuring EIGRP passive interface
- Configuring EIGRP metric weights
- Configuring EIGRP default metric
- Configuring EIGRP stub
- Configuring EIGRP authentication key chain
- Configuring EIGRP authentication mode
- Configuring BFD for EIGRP
- Configuring EIGRP in Interface Configuration Mode
- Configuring BGP
- Configuring a BGP Router
- VXLAN EVPN Traffic Engineering - Multi-Site Egress Load-Balancing
- VXLAN EVPN Traffic Engineering – RPM support
- Configuring BGP on a VRF
- Configuring BFD Multihop under a Neighbor
- Configuring an IPv4 Multicast Address Family
- Configuring an IPv4 MVPN Address Family
- Configuring an IPv4 Unicast Address Family
- Configuring an IPv6 MVPN Address Family
- Configuring an IPv6 Unicast Address Family
- Configuring a Link-State Address Family
- Configuring a VPNv4 Unicast Address Family
- Configuring a VPNv6 Unicast Address Family
- Configuring a Peer Policy Template
- Configuring an IPv4 Labeled Unicast Subaddress Family for a Peer Policy Template
- Configuring an IPv4 Unicast Subaddress Family for a Peer Policy Template
- Configuring an IPv6 Unicast Subaddress Family for a Peer Policy Template
- Configuring a VPNv4 Unicast Subaddress Family for a Peer Policy Template
- Configuring a VPNv6 Unicast Subaddress Family for a Peer Policy Template
- Configuring a Peer Policy Template with Peer Template Inheritance
- Configuring an IPv4 Labeled Unicast Subaddress Family for a Peer Policy Template with Peer Template Inheritance
- Configuring an IPv4 Unicast Subaddress Family for a Peer Policy Template with Peer Template Inheritance
- Configuring an IPv6 Unicast Subaddress Family for a Peer Policy Template with Peer Template Inheritance
- Configuring a VPNv4 Unicast Subaddress Family for a Peer Policy Template with Peer Template Inheritance
- Configuring a VPNv6 Unicast Subaddress Family for a Peer Policy Template with Peer Template Inheritance
- Configuring a Peer Template
- Configuring an IPv4 Labeled Subaddress Family for a Peer Template
- Configuring an IPv4 Unicast Subaddress Family for a Peer Template
- Configuring an IPv6 Unicast Subaddress Family for a Peer Template
- Configuring a VPNv4 Subaddress Family for a Peer Template
- Configuring a VPNV6 Subaddress Family for a Peer Template
- Configuring Peer Template Inheritance
- Configuring an IPv4 Labeled Unicast Subaddress Family for Peer Template Inheritance
- Configuring an IPv4 Unicast Subaddress Family for Peer Template Inheritance
- Configuring an IPv6 Unicast Subaddress Family for Peer Template Inheritance
- Configuring a VPNv4 Unicast Subaddress Family for Peer Template Inheritance
- Configuring a VPNv6 Unicast Subaddress Family for Peer Template Inheritance
- Configuring a Peer Template with Peer Template Inheritance
- Configuring an IPv4 Labeled Unicast Subaddress Family for a Peer Template with Peer Template Inheritance
- Configuring an IPv4 Unicast Subaddress Family for a Peer Template with Peer Template Inheritance
- Configuring an IPv6 Unicast Subaddress Family for a Peer Template with Peer Template Inheritance
- Configuring a VPNv4 Unicast Subaddress Family for a Peer Template with Peer Template Inheritance
- Configuring a VPNv6 Unicast Subaddress Family for a Peer Template with Peer Template Inheritance
- Configuring a BGP Neighbor (IP Address)
- Configuring an IPv4 Unicast Subaddress Family Under a BGP Neighbor (IP Address)
- Configuring an IPv6 Labeled Unicast Subaddress Family Under a BGP Neighbor (IP Address)
- Configuring an IPv6 Multicast Subaddress Family Under a BGP Neighbor (IP Address)
- Configuring an IPv6 Unicast Subaddress Family Under a BGP Neighbor (IP Address)
- Configuring an IPv4 MVPN Subaddress Family Under a BGP Neighbor (IP Address)
- Configuring an IPv6 MVPN Subaddress Family Under a BGP Neighbor (IP Address)
- Configuring an L2VPN EVPN Address Family under a BGP Neighbor (IP Address)
- Configuring a VPNv4 Unicast Subaddress Family Under a BGP Neighbor (IP Address)
- Configuring a VPNv6 Unicast Subaddress Family Under a BGP Neighbor (IP Address)
- Configuring BGP Session Templates Under a BGP Neighbor (IP Address)
- Configuring a BGP Neighbor (Ethernet Interface)
- Configuring an IPv4 Unicast Subaddress Family Under a BGP Neighbor (Ethernet Interface)
- Configuring an IPv6 MVPN Subaddress Family Under a BGP Neighbor (Ethernet Interface)
- Configuring an L2VPN EVPN Subaddress Family Under a BGP Neighbor (Ethernet Interface)
- Configuring a VPNv4 Unicast Subaddress Family Under a BGP Neighbor (Ethernet Interface)
- Configuring a VPNv6 Unicast Subaddress Family Under a BGP Neighbor (Ethernet Interface)
- Configuring a BMP Server
- Configuring Mixed ECMP
- About Querying Ephemeral Data
- Configuring RIP
- Configuring DSCP
- Configuring VRFs
- Configuring Route Policy Manager
- First-Hop Redundancy Protocols
- Configuring Hardware Forwarding
- Configuring Hardware Ejector
- Configuring Hardware Profile Settings
- Configuring the Site of Origin
- Configuring AS-4 Dot Notation
- Configuring Static Routing
- Configuring Load Sharing in the Unicast FIB
- Configuring OpenFlow
- Configuring RTP Flow Monitoring
- Configuring Kernel Stack
- Configuring Apphosting
- Controlling the Guest Shell
- Enabling the Guest Shell and Querying the Result
- Disabling the Guest Shell and Querying the Result
- Destroying the Guest Shell and Querying the Result
- Rebooting the Guest Shell and Querying the Result
- Increasing the Guest Shell Rootfs Size and Querying the Result
- Changing the CPU Memory Size that the Guest Shell Uses and Querying the Result
- Changing the Memory Size the Guest Shell Uses and Querying the Result
- Syncing the Guest Shell Rootfs to the Standby Supervisor and Querying the Result
- Exporting the Guest Shell Rootfs and Querying the Result
- Upgrading the Guest Shell Rootfs and Querying the Result
- Querying Guest Shell Information
- Change Virtual Service Global Configuration
- Managing System Hardware
- Configuring the Baseboard Management Controller
- Configuring Virtual Machine Tracker
- Configuring Virtual Device Contexts
- Configuring iCAM
- Configuring SRv6
- Configuring Smart Software Licensing
- Querying Configurations (Show Commands)
- Querying Advertised Routes
- Querying DHCP Relay Interfaces
- Querying Diagnostic Result Test IDs
- Querying the Environment Settings
- Querying Feature Status
- Querying Inventory Information
- Querying IS-IS Configurations
- Querying IP IGMP Groups
- Querying IP OSPF Neighbor Details
- Querying IP OSPF Neighbor VRF Information
- Querying L2VPN EVPN
- Querying LLDP
- Querying MAC Address Table Info
- Querying Module Information
- Querying NAT ITD
- Querying NTP Peer Status
- Querying an OSPFv2 Instance
- Querying Patterns
- Querying PIM Information
- Querying the Processes Log
- Querying Spanning Tree Information
- Querying a Summary of IP Interface Status and Configuration Information
- Querying TCAM Resource Utilization
- Querying MCAST NAT TCAM Resource Monitoring
- Querying NBM TCAM Resource Monitoring
- Querying the Version
- Querying VLAN ID Counters
- Querying VRF Information
- Querying VRRP Information
- Querying Forwarding Route Information
- Querying IP Route Details
- Querying the Current MOTD Banner Message
- Querying OSPF Neighbors
- Querying Analytic Information
- Querying Interface and VLAN Counters and Statistics
- Querying ITD Runtime Information
- Querying ePBR Runtime Information
- Using the Managed Object Browser
- Monitoring the Environment
Querying Module Information
DME
YANG
CopyGET http://<IP_Address>/api/mo/sys/ch/lcslot-1/lc/splc/splcblk.json
Response
{
"totalCount": "1",
"imdata": [
{
"eqptLC": {
"attributes": {
"breakoutFactor": "1",
"childAction": "",
"descr": "1/10G SFP+ Ethernet Module",
"dn": "sys/ch/lcslot-1/lc",
"hwVer": "2.0",
"id": "1",
"macB": "00-00-00-00-00-00",
"macE": "00-00-00-00-00-00",
"mfgTm": "2014-03-17T00:00:00.000+00:00",
"modTs": "2018-06-06T14:16:57.766+00:00",
"model": "N9K-C9396PX",
"numP": "48",
"operSt": "online",
"partNumber": "73-15605-04",
"persistentOnReload": "false",
"pwrSt": "on",
"rev": "A0",
"ser": "SAL1812NT9M",
"status": "",
"swCId": "298",
"swVer": "9.2(0.87)",
"type": "linecard",
"upTs": "2018-06-06T14:16:57.766+00:00",
"vdrId": "V02",
"vendor": "Cisco Systems, Inc."
}
}
}
]
}
GET http://<IP_Address>/api/mo/sys/ch/lcslot-2/lc/splc/spcmn.json
Response
{
"totalCount": "1",
"imdata": [
{
"eqptSpCmnBlk": {
"attributes": {
"cksum": "6806",
"clei": "12345678",
"count": "3",
"dn": "sys/ch/lcslot-2/lc/splc/spcmn",
"engBits": "0",
"hwVer": "0.2080",
"len": "160",
"major": "24578",
"mfgBits": "0",
"mfgDev": "00000000000000000000",
"minor": "0",
"oem": "Cisco Systems, Inc.",
"pRev": "08",
"pdNum": "N9K-M6PQ",
"prtNum": "73-15578-02",
"pwrCon": "-1333",
"rmaFl": "0-0-0-0",
"serNum": "SAL1827W7TG",
"sig": "43947",
"size": "65535",
"vdrId": "V00",
"ver": "3"
}
}
}
]
}
GET http://<IP_Address>/api/mo/sys/ch/lcslot-1/lc/splc/splcblk.json
Response
{
"totalCount": "1",
"imdata": [
{
"eqptSpromLcBlk": {
"attributes": {
"ambT": "55",
"cksum": "2816",
"coolRq": "100",
"crdIdx": "21022",
"dn": "sys/ch/lcslot-1/lc/splc/splcblk",
"eobcN": "0",
"epldN": "0",
"fbits": "0",
"hwCBits": "64",
"len": "103",
"macB": "74-26-ac-76-64-00",
"macL": "56",
"maxCPwr": "8300",
"sensor1": "60,42",
"sensor2": "80,70",
"sensor3": "90,80",
"sensor4": "100,90",
"sensor5": "110,100",
"sensor6": "110,100",
"sensor7": "105,90",
"sensor8": "-128,-128",
"sig": "24579",
"ver": "2"
}
}
}
]
}
GET http://<IP_Address>/api/mo/sys/gold/module-1.json
Response
{
"totalCount": "1",
"imdata": [
{
"goldModule": {
"attributes": {
"description": "1/10G SFP+ Ethernet Module",
"diagBootLevel": "complete",
"diagStatus": "pass",
"dn": "sys/gold/module-1",
"id": "1"
}
}
}
]
}
CopyGET http://<IP_Address>/restconf/data/Cisco-NX-OS-device:System/ch-items
<ch-items>
<descr>Nexus9000 C9396PX Chassis</descr>
<ftslot-items>
<FtSlot-list>
<id>3</id>
<descr>Fan Slot</descr>
<ft-items>
<descr>N9K-C9300-FAN2-3</descr>
<fan-items>
<Fan-list>
<id>1</id>
<descr>fan</descr>
<dir>front2back</dir>
<mfgTm>not-applicable</mfgTm>
<model>N9K-C9300-FAN2</model>
<operSt>ok</operSt>
<rev/>
<ser/>
<speedInPercent>59</speedInPercent>
<speedInRpm>9782</speedInRpm>
<vendor>Cisco</vendor>
</Fan-list>
</fan-items>
<fanName>N9K-C9300-FAN2-3</fanName>
<hwVer>1.0</hwVer>
<id>3</id>
<mfgTm>not-applicable</mfgTm>
<model>N9K-C9300-FAN2</model>
<operSt>ok</operSt>
<rev/>
<ser/>
<vdrId>V01</vdrId>
<vendor/>
</ft-items>
<loc>rear</loc>
<operSt>empty</operSt>
<physId>3</physId>
<type>fantray</type>
</FtSlot-list>
<FtSlot-list>
<id>2</id>
<descr>Fan Slot</descr>
<ft-items>
<descr>N9K-C9300-FAN2-2</descr>
<fan-items>
<Fan-list>
<id>1</id>
<descr>fan</descr>
<dir>front2back</dir>
<mfgTm>not-applicable</mfgTm>
<model>N9K-C9300-FAN2</model>
<operSt>ok</operSt>
<rev/>
<ser/>
<speedInPercent>59</speedInPercent>
<speedInRpm>9818</speedInRpm>
<vendor>Cisco</vendor>
</Fan-list>
</fan-items>
<fanName>N9K-C9300-FAN2-2</fanName>
<hwVer>1.0</hwVer>
<id>2</id>
<mfgTm>not-applicable</mfgTm>
<model>N9K-C9300-FAN2</model>
<operSt>ok</operSt>
<rev/>
<ser/>
<vdrId>V01</vdrId>
<vendor/>
</ft-items>
<loc>rear</loc>
<operSt>empty</operSt>
<physId>2</physId>
<type>fantray</type>
</FtSlot-list>
<FtSlot-list>
<id>1</id>
<descr>Fan Slot</descr>
<ft-items>
<descr>N9K-C9300-FAN2-1</descr>
<fan-items>
<Fan-list>
<id>1</id>
<descr>fan</descr>
<dir>front2back</dir>
<mfgTm>not-applicable</mfgTm>
<model>N9K-C9300-FAN2</model>
<operSt>ok</operSt>
<rev/>
<ser/>
<speedInPercent>60</speedInPercent>
<speedInRpm>10055</speedInRpm>
<vendor>Cisco</vendor>
</Fan-list>
</fan-items>
<fanName>N9K-C9300-FAN2-1</fanName>
<hwVer>1.0</hwVer>
<id>1</id>
<mfgTm>not-applicable</mfgTm>
<model>N9K-C9300-FAN2</model>
<operSt>ok</operSt>
<rev/>
<ser/>
<vdrId>V01</vdrId>
<vendor/>
</ft-items>
<loc>rear</loc>
<operSt>empty</operSt>
<physId>1</physId>
<type>fantray</type>
</FtSlot-list>
</ftslot-items>
<id>1</id>
<lcslot-items>
<LCSlot-list>
<id>1</id>
<descr>Linecard slot</descr>
<lc-items>
<breakoutFactor>1</breakoutFactor>
<descr>1/10G SFP+ Ethernet Module</descr>
<hwVer>2.0</hwVer>
<id>1</id>
<leafport-items>
<LeafP-list>
<id>5</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>41</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>52</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>53</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>26</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>9</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>24</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>40</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>25</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>27</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>14</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>6</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>1</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>36</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>46</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>21</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>7</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>37</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>44</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>50</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>47</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>38</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>54</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>45</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>31</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>8</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>15</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>23</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>3</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>17</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>30</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>16</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>18</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>49</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>33</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>12</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>43</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>51</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>13</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>39</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>29</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>2</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>19</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>4</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>35</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>10</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>34</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>20</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>11</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>32</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>28</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>22</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>42</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
<LeafP-list>
<id>48</id>
<descr>Leaf Port</descr>
<speed>0</speed>
<type>leaf</type>
</LeafP-list>
</leafport-items>
<macB>00-00-00-00-00-00</macB>
<macE>00-00-00-00-00-00</macE>
<mfgTm>2014-03-17T00:00:00.000+00:00</mfgTm>
<model>N9K-C9396PX</model>
<numP>48</numP>
<operSt>online</operSt>
<partNumber>73-15605-04</partNumber>
<pwrSt>on</pwrSt>
<rev>A0</rev>
<ser>SAL1812NT9M</ser>
<splc-items>
<acc>read-only</acc>
<cap>512</cap>
<descr>Linecard Sprom</descr>
<id>1</id>
<numBlk>768</numBlk>
<operSt>ok</operSt>
<rev/>
<ser>SAL1812NT9M</ser>
<spcmn-items>
<cksum>6342</cksum>
<clei>CMMPE00DRB</clei>
<count>3</count>
<engBits>0</engBits>
<hwVer>2.0</hwVer>
<len>160</len>
<major>24578</major>
<mfgBits>0</mfgBits>
<mfgDev>00</mfgDev>
<minor>0</minor>
<oem>Cisco Systems, Inc.</oem>
<pRev>A0</pRev>
<pdNum>N9K-C9396PX</pdNum>
<prtNum>73-15605-04</prtNum>
<pwrCon>-3500</pwrCon>
<rmaFl>0-0-0-0</rmaFl>
<serNum>SAL1812NT9M</serNum>
<sig>43947</sig>
<size>65535</size>
<vdrId>V02</vdrId>
<ver>3</ver>
</spcmn-items>
<splcblk-items>
<ambT>55</ambT>
<cksum>2816</cksum>
<coolRq>100</coolRq>
<crdIdx>21022</crdIdx>
<eobcN>0</eobcN>
<epldN>0</epldN>
<fbits>0</fbits>
<hwCBits>64</hwCBits>
<len>103</len>
<macB>74-26-ac-76-64-00</macB>
<macL>56</macL>
<maxCPwr>8300</maxCPwr>
<sensor1>60,42</sensor1>
<sensor2>80,70</sensor2>
<sensor3>90,80</sensor3>
<sensor4>100,90</sensor4>
<sensor5>110,100</sensor5>
<sensor6>110,100</sensor6>
<sensor7>105,90</sensor7>
<sensor8>-128,-128</sensor8>
<sig>24579</sig>
<sppd-items>
<numPts>48</numPts>
<prtTy>2</prtTy>
</sppd-items>
<ver>2</ver>
</splcblk-items>
<spsensorblk-items>
<cksum>8368</cksum>
<len>71</len>
<sensor10>-128,-128</sensor10>
<sensor11>-128,-128</sensor11>
<sensor12>-128,-128</sensor12>
<sensor13>-128,-128</sensor13>
<sensor14>-128,-128</sensor14>
<sensor15>-128,-128</sensor15>
<sensor16>-128,-128</sensor16>
<sensor17>-128,-128</sensor17>
<sensor18>-128,-128</sensor18>
<sensor19>-128,-128</sensor19>
<sensor20>-128,-128</sensor20>
<sensor21>-128,-128</sensor21>
<sensor22>-128,-128</sensor22>
<sensor23>-128,-128</sensor23>
<sensor24>-128,-128</sensor24>
<sensor25>-128,-128</sensor25>
<sensor26>-128,-128</sensor26>
<sensor27>-128,-128</sensor27>
<sensor28>-128,-128</sensor28>
<sensor29>-128,-128</sensor29>
<sensor30>-128,-128</sensor30>
<sensor31>-128,-128</sensor31>
<sensor32>-128,-128</sensor32>
<sensor33>-128,-128</sensor33>
<sensor34>-128,-128</sensor34>
<sensor35>-128,-128</sensor35>
<sensor36>-128,-128</sensor36>
<sensor37>-128,-128</sensor37>
<sensor38>-128,-128</sensor38>
<sensor39>-128,-128</sensor39>
<sensor40>-128,-128</sensor40>
<sensor9>-128,-128</sensor9>
<sig>24584</sig>
<ver>1</ver>
</spsensorblk-items>
<type>unk</type>
<vendor/>
</splc-items>
<swCId>298</swCId>
<swVer>9.2(0.87)</swVer>
<type>linecard</type>
<upTs>2018-06-06T14:16:57.766+00:00</upTs>
<vdrId>V02</vdrId>
<vendor>Cisco Systems, Inc.</vendor>
</lc-items>
<loc>front</loc>
<operSt>empty</operSt>
<physId>1</physId>
<poweroff>no</poweroff>
<purgeCfg>false</purgeCfg>
<type>lcslot</type>
</LCSlot-list>
<LCSlot-list>
<id>2</id>
<descr>Linecard slot</descr>
<lc-items>
<breakoutFactor>1</breakoutFactor>
<descr>40G Ethernet Expansion Module</descr>
<hwVer>0.2080</hwVer>
<id>2</id>
<macB>00-00-00-00-00-00</macB>
<macE>00-00-00-00-00-00</macE>
<mfgTm>2014-06-30T01:00:00.000+00:00</mfgTm>
<model>N9K-M6PQ</model>
<numP>6</numP>
<operSt>online</operSt>
<partNumber>73-15578-02</partNumber>
<pwrSt>on</pwrSt>
<rev>08</rev>
<ser>SAL1827W7TG</ser>
<splc-items>
<acc>read-only</acc>
<cap>512</cap>
<descr>Linecard Sprom</descr>
<id>1</id>
<numBlk>768</numBlk>
<operSt>ok</operSt>
<rev/>
<ser>SAL1827W7TG</ser>
<spcmn-items>
<cksum>6806</cksum>
<clei>12345678</clei>
<count>3</count>
<engBits>0</engBits>
<hwVer>0.2080</hwVer>
<len>160</len>
<major>24578</major>
<mfgBits>0</mfgBits>
<mfgDev>00000000000000000000</mfgDev>
<minor>0</minor>
<oem>Cisco Systems, Inc.</oem>
<pRev>08</pRev>
<pdNum>N9K-M6PQ</pdNum>
<prtNum>73-15578-02</prtNum>
<pwrCon>-1333</pwrCon>
<rmaFl>0-0-0-0</rmaFl>
<serNum>SAL1827W7TG</serNum>
<sig>43947</sig>
<size>65535</size>
<vdrId>V00</vdrId>
<ver>3</ver>
</spcmn-items>
<splcblk-items>
<ambT>55</ambT>
<cksum>3216</cksum>
<coolRq>0</coolRq>
<crdIdx>21034</crdIdx>
<eobcN>0</eobcN>
<epldN>0</epldN>
<fbits>0</fbits>
<hwCBits>1</hwCBits>
<len>103</len>
<macB>88-f0-31-bd-34-9e</macB>
<macL>6</macL>
<maxCPwr>2400</maxCPwr>
<sensor1>105,95</sensor1>
<sensor2>105,95</sensor2>
<sensor3>110,100</sensor3>
<sensor4>-128,-128</sensor4>
<sensor5>-128,-128</sensor5>
<sensor6>-128,-128</sensor6>
<sensor7>-128,-128</sensor7>
<sensor8>-128,-128</sensor8>
<sig>24578</sig>
<sppd-items>
<numPts>6</numPts>
<prtTy>2</prtTy>
</sppd-items>
<ver>2</ver>
</splcblk-items>
<spsensorblk-items>
<cksum>8368</cksum>
<len>71</len>
<sensor10>-128,-128</sensor10>
<sensor11>-128,-128</sensor11>
<sensor12>-128,-128</sensor12>
<sensor13>-128,-128</sensor13>
<sensor14>-128,-128</sensor14>
<sensor15>-128,-128</sensor15>
<sensor16>-128,-128</sensor16>
<sensor17>-128,-128</sensor17>
<sensor18>-128,-128</sensor18>
<sensor19>-128,-128</sensor19>
<sensor20>-128,-128</sensor20>
<sensor21>-128,-128</sensor21>
<sensor22>-128,-128</sensor22>
<sensor23>-128,-128</sensor23>
<sensor24>-128,-128</sensor24>
<sensor25>-128,-128</sensor25>
<sensor26>-128,-128</sensor26>
<sensor27>-128,-128</sensor27>
<sensor28>-128,-128</sensor28>
<sensor29>-128,-128</sensor29>
<sensor30>-128,-128</sensor30>
<sensor31>-128,-128</sensor31>
<sensor32>-128,-128</sensor32>
<sensor33>-128,-128</sensor33>
<sensor34>-128,-128</sensor34>
<sensor35>-128,-128</sensor35>
<sensor36>-128,-128</sensor36>
<sensor37>-128,-128</sensor37>
<sensor38>-128,-128</sensor38>
<sensor39>-128,-128</sensor39>
<sensor40>-128,-128</sensor40>
<sensor9>-128,-128</sensor9>
<sig>24584</sig>
<ver>1</ver>
</spsensorblk-items>
<type>unk</type>
<vendor/>
</splc-items>
<swCId>329</swCId>
<swVer>9.2(0.87)</swVer>
<type>linecard</type>
<upTs>2018-06-06T14:16:57.798+00:00</upTs>
<vdrId>V00</vdrId>
<vendor>Cisco Systems, Inc.</vendor>
</lc-items>
<loc>front</loc>
<operSt>empty</operSt>
<physId>2</physId>
<poweroff>no</poweroff>
<purgeCfg>false</purgeCfg>
<type>lcslot</type>
</LCSlot-list>
</lcslot-items>
<mfgTm>2014-03-17T00:00:00.000+00:00</mfgTm>
<model/>
<operSt>online</operSt>
<operStQual>Chassis came online</operStQual>
<psuslot-items>
<PsuSlot-list>
<id>2</id>
<descr>PSU slot</descr>
<loc>rear</loc>
<operSt>empty</operSt>
<physId>2</physId>
<psu-items>
<cap>54.16</cap>
<descr>N9K-PAC-650W-2</descr>
<drawnCurr>6.17</drawnCurr>
<fanDirection>front2back</fanDirection>
<fanOpSt>ok</fanOpSt>
<hwVer/>
<id>2</id>
<inputCurr>0.37</inputCurr>
<mfgTm>not-applicable</mfgTm>
<model>N9K-PAC-650W</model>
<operSt>ok</operSt>
<rev>A0</rev>
<ser>DCB1749X0C6</ser>
<vSrc>220v</vSrc>
<vdrId>V01</vdrId>
<vendor>Cisco Systems Inc</vendor>
<volt>12.0</volt>
</psu-items>
<type>psuslot</type>
</PsuSlot-list>
<PsuSlot-list>
<id>1</id>
<descr>PSU slot</descr>
<loc>rear</loc>
<operSt>empty</operSt>
<physId>1</physId>
<psu-items>
<cap>54.16</cap>
<descr>N9K-PAC-650W-1</descr>
<drawnCurr>6.2</drawnCurr>
<fanDirection>front2back</fanDirection>
<fanOpSt>ok</fanOpSt>
<hwVer/>
<id>1</id>
<inputCurr>0.35</inputCurr>
<mfgTm>not-applicable</mfgTm>
<model>N9K-PAC-650W</model>
<operSt>ok</operSt>
<rev>A0</rev>
<ser>DCB1749X0BB</ser>
<vSrc>220v</vSrc>
<vdrId>V01</vdrId>
<vendor>Cisco Systems Inc</vendor>
<volt>12.0</volt>
</psu-items>
<type>psuslot</type>
</PsuSlot-list>
</psuslot-items>
<rev>A0</rev>
<role>unsupported</role>
<ser>SAL1812NT9M</ser>
<spbp-items>
<acc>read-only</acc>
<cap>0</cap>
<descr>TOR</descr>
<id>1</id>
<model>TOR</model>
<numBlk>3</numBlk>
<operSt>ok</operSt>
<rev>A0</rev>
<ser>SAL1812NT9M</ser>
<spbpblk-items>
<cksum>1049</cksum>
<fbits>0</fbits>
<hwCBits>0</hwCBits>
<len>39</len>
<macB>00-00-ab-cd-dc-ba</macB>
<macL>128</macL>
<maxCPwr>0</maxCPwr>
<oemEprise>0</oemEprise>
<oemMIB>0</oemMIB>
<sig>24577</sig>
<stackMIB>0</stackMIB>
<ver>3</ver>
</spbpblk-items>
<spcmn-items>
<cksum>6342</cksum>
<clei>CMMPE00DRB</clei>
<count>3</count>
<engBits>0</engBits>
<hwVer>2.0</hwVer>
<len>160</len>
<major>24578</major>
<mfgBits>0</mfgBits>
<mfgDev>00</mfgDev>
<minor>0</minor>
<oem>Cisco Systems, Inc.</oem>
<pRev>A0</pRev>
<pdNum>N9K-C9396PX</pdNum>
<prtNum>73-15605-04</prtNum>
<pwrCon>-3500</pwrCon>
<rmaFl>0-0-0-0</rmaFl>
<serNum>SAL1812NT9M</serNum>
<sig>43947</sig>
<size>65535</size>
<vdrId>V02</vdrId>
<ver>3</ver>
</spcmn-items>
<type>7</type>
<vendor>Cisco Systems, Inc.</vendor>
</spbp-items>
<supslot-items>
<SupCSlot-list>
<id>1</id>
<descr>Sup slot</descr>
<loc>front</loc>
<operSt>empty</operSt>
<physId>1</physId>
<poweroff>no</poweroff>
<sup-items>
<cpu-items>
<CPU-list>
<id>1</id>
<arch>x86_64</arch>
<cores>4</cores>
<coresEn>4</coresEn>
<descr> Intel(R) Core(TM) i3- CPU # 2.50GHz</descr>
<mfgTm>not-applicable</mfgTm>
<model> Intel(R) Core(TM) i3- CPU # 2.50GHz</model>
<rev> 58</rev>
<ser>n/a</ser>
<sock>unspecified</sock>
<speed>2500.0</speed>
<thrds>4</thrds>
<vendor> GenuineIntel</vendor>
</CPU-list>
</cpu-items>
<descr>1/10G SFP+ Ethernet Module</descr>
<dimm-items>
<Dimm-list>
<id>1</id>
<acc>read-write</acc>
<cap>16015</cap>
<descr>RAM</descr>
<mfgTm>2018-06-06T14:16:57.620+00:00</mfgTm>
<model>n/a</model>
<operSt>ok</operSt>
<rev>n/a</rev>
<ser>n/a</ser>
<type>dimm</type>
<vendor>n/a</vendor>
</Dimm-list>
</dimm-items>
<flash-items>
<acc>read-write</acc>
<cap>61057</cap>
<descr>flash</descr>
<id>1</id>
<mfgTm>2018-06-06T14:16:57.621+00:00</mfgTm>
<model>n/a</model>
<operSt>ok</operSt>
<rev>n/a</rev>
<ser>n/a</ser>
<type>flash</type>
<vendor>n/a</vendor>
</flash-items>
<hwVer>2.0</hwVer>
<id>1</id>
<macB>74-26-ac-76-64-00</macB>
<macE>74-26-ac-76-64-37</macE>
<mfgTm>2014-03-17T00:00:00.000+00:00</mfgTm>
<mgmt-items>
<MgmtP-list>
<id>1</id>
<descr/>
<type>mgmt</type>
</MgmtP-list>
</mgmt-items>
<model>N9K-C9396PX</model>
<numP>48</numP>
<operSt>online</operSt>
<partNumber>A0</partNumber>
<pwrSt>on</pwrSt>
<rdSt>active</rdSt>
<rev>A0</rev>
<sensor-items>
<Sensor-list>
<id>3</id>
<descr>CPU</descr>
<majorThresh>90</majorThresh>
<minorThresh>80</minorThresh>
<model>CPU</model>
<operSt>normal</operSt>
<tempValue>43</tempValue>
<type>cpu</type>
<unit>Celsius</unit>
<vendor>Cisco Systems</vendor>
</Sensor-list>
<Sensor-list>
<id>5</id>
<descr>NS-1</descr>
<majorThresh>105</majorThresh>
<minorThresh>90</minorThresh>
<model>NS-1</model>
<operSt>normal</operSt>
<tempValue>37</tempValue>
<type>asic</type>
<unit>Celsius</unit>
<vendor>Cisco Systems</vendor>
</Sensor-list>
<Sensor-list>
<id>1</id>
<descr>FRONT</descr>
<majorThresh>70</majorThresh>
<minorThresh>42</minorThresh>
<model>FRONT</model>
<operSt>normal</operSt>
<tempValue>28</tempValue>
<type>inlet</type>
<unit>Celsius</unit>
<vendor>Cisco Systems</vendor>
</Sensor-list>
<Sensor-list>
<id>4</id>
<descr>TD2-1</descr>
<majorThresh>105</majorThresh>
<minorThresh>90</minorThresh>
<model>TD2-1</model>
<operSt>normal</operSt>
<tempValue>43</tempValue>
<type>asic</type>
<unit>Celsius</unit>
<vendor>Cisco Systems</vendor>
</Sensor-list>
<Sensor-list>
<id>2</id>
<descr>BACK</descr>
<majorThresh>80</majorThresh>
<minorThresh>70</minorThresh>
<model>BACK</model>
<operSt>normal</operSt>
<tempValue>33</tempValue>
<type>outlet</type>
<unit>Celsius</unit>
<vendor>Cisco Systems</vendor>
</Sensor-list>
</sensor-items>
<ser>SAL1812NT9M</ser>
<spsup-items>
<acc>read-only</acc>
<cap>512</cap>
<descr>Sup SPROM</descr>
<id>1</id>
<model>N9K-C9396PX</model>
<numBlk>768</numBlk>
<operSt>ok</operSt>
<rev>A0</rev>
<ser>SAL1812NT9M</ser>
<spcmn-items>
<cksum>6342</cksum>
<clei>CMMPE00DRB</clei>
<count>3</count>
<engBits>0</engBits>
<hwVer>2.0</hwVer>
<len>160</len>
<major>24578</major>
<mfgBits>0</mfgBits>
<mfgDev>00</mfgDev>
<minor>0</minor>
<oem>Cisco Systems, Inc.</oem>
<pRev>A0</pRev>
<pdNum>N9K-C9396PX</pdNum>
<prtNum>73-15605-04</prtNum>
<pwrCon>-3500</pwrCon>
<rmaFl>0-0-0-0</rmaFl>
<serNum>SAL1812NT9M</serNum>
<sig>43947</sig>
<size>65535</size>
<vdrId>V02</vdrId>
<ver>3</ver>
</spcmn-items>
<spsensorblk-items>
<cksum>8368</cksum>
<len>71</len>
<sensor10>-128,-128</sensor10>
<sensor11>-128,-128</sensor11>
<sensor12>-128,-128</sensor12>
<sensor13>-128,-128</sensor13>
<sensor14>-128,-128</sensor14>
<sensor15>-128,-128</sensor15>
<sensor16>-128,-128</sensor16>
<sensor17>-128,-128</sensor17>
<sensor18>-128,-128</sensor18>
<sensor19>-128,-128</sensor19>
<sensor20>-128,-128</sensor20>
<sensor21>-128,-128</sensor21>
<sensor22>-128,-128</sensor22>
<sensor23>-128,-128</sensor23>
<sensor24>-128,-128</sensor24>
<sensor25>-128,-128</sensor25>
<sensor26>-128,-128</sensor26>
<sensor27>-128,-128</sensor27>
<sensor28>-128,-128</sensor28>
<sensor29>-128,-128</sensor29>
<sensor30>-128,-128</sensor30>
<sensor31>-128,-128</sensor31>
<sensor32>-128,-128</sensor32>
<sensor33>-128,-128</sensor33>
<sensor34>-128,-128</sensor34>
<sensor35>-128,-128</sensor35>
<sensor36>-128,-128</sensor36>
<sensor37>-128,-128</sensor37>
<sensor38>-128,-128</sensor38>
<sensor39>-128,-128</sensor39>
<sensor40>-128,-128</sensor40>
<sensor9>-128,-128</sensor9>
<sig>24584</sig>
<ver>1</ver>
</spsensorblk-items>
<spsupblk-items>
<ambT>55</ambT>
<cksum>2807</cksum>
<coolRq>100</coolRq>
<crdIdx>21022</crdIdx>
<eobcN>0</eobcN>
<epldN>0</epldN>
<fbits>0</fbits>
<hwCBits>64</hwCBits>
<len>103</len>
<macB>74-26-ac-76-64-00</macB>
<macL>56</macL>
<maxCPwr>8300</maxCPwr>
<sensor1>60,42</sensor1>
<sensor2>80,70</sensor2>
<sensor3>90,80</sensor3>
<sensor4>100,90</sensor4>
<sensor5>110,100</sensor5>
<sensor6>110,100</sensor6>
<sensor7>105,90</sensor7>
<sensor8>-128,-128</sensor8>
<sig>24578</sig>
<sppd-items>
<numPts>48</numPts>
<prtTy>2</prtTy>
</sppd-items>
<ver>2</ver>
</spsupblk-items>
<type>flash</type>
<vendor>Cisco Systems, Inc.</vendor>
</spsup-items>
<swCId>298</swCId>
<swVer>9.2(0.87)</swVer>
<type>supervisor</type>
<upTs>2018-06-06T14:16:57.616+00:00</upTs>
<vdrId>V02</vdrId>
<vendor>Cisco Systems, Inc.</vendor>
</sup-items>
<type>supslot</type>
</SupCSlot-list>
</supslot-items>
<vendor>Cisco Systems, Inc.</vendor>
</ch-items>